44
Defect of F1 to F8 is as following:
Attention: if there are other faults needs special tools, in order to avoid danger, must be repaired by professional
people of manufacturer, repairing agent or similar agent.
Technical Parameter
Code Defect Solutions
F1 Battery pack nickel strip broken Replace or repair battery pack
F2 Charger defect Replace charger
F3 Vacuum motor short circuit Replace vacuum motor
F4 Battery cell defect Replace or repair battery pack
F5
Vacuum motor 1st over current
protection
Replace vacuum motor
F6
Vacuum motor 2nd over
current protection
Replace vacuum motor
F7
PCB defect or PCB leadwire
loose
Replace PCB or PCB leadwire
F8 Battery pack NTC abnormal
Turn off the vacuum and wait until
battery pack cooled down. Turn on
again
If error code still appears, replace
battery pack
Model No H8 Flex
Rated voltage
25.2V
Rated power 550W
Charger input voltage 100-240V ~ 50/60 Hz
Charger output voltage 30V/600mA
Electric oor head model No T-EB110VE
Electric oor head rated power 30W
Battery pack capacity 2500mAh
Charge time 4-5h