113545-3 Telephone 01422 822282 15
Heat Input / Gas Consumption / Orifice (Injector) Data
Shaded areas are stated in metric equivalents
* Gas valve’s internal regulator disabled.
** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
Gas Specifications for Dryers Going to CE Countries**
Gas
Type
Nominal
Heating Value
Supply
Pressure
Gross
Heat Input
Fuel
Consumption
Orifice Size
Orifice
(Injector)
Quantity
Burner
Pressure
Btu/ft
3
mb Btu/hr kW DMS mm mb
Natural (I
2H
/I
2E
) 1,000
15-30
40,000
11.72 1.133 M
3
/H
30
3.264
1
6.7
Natural (I
2L
) 830
20-35
40,000
11.72 1.365 M
3
/H
30
3.264
1
9.2
Natural (I
2ELL
) 830
15-30
40,000
11.72 1.365 M
3
/H
30
3.264
1
9.2
*Natural (I
2E+
)
1,000
20
40,000
11.72 1.133 M
3
/H
38
2.578
1
—
830
25
40,000
11.72 1.365 M
3
/H
38
2.578
1
—
*Butane (I
3+
) 3,175
28-30
40,000
11.72 0.845 kg/H
52
1.613
1
—
*Propane (I
3+
) 2,500
37
40,000
11.72 0.845 kg/H
52
1.613
1
—
Butane (I
3B/P
) 3,175
28-30/50
40,000
11.72 0.845 kg/H
49
1.854
1
18.0
Propane (I
3P
) 2,500
28-30/50
40,000
11.72 0.845 kg/H
49
1.854
1
23.0
Gas Specifications for Dryers Going to Rest of the World**
Gas
Type
Nominal
Heating Value
Supply
Pressure
Gross
Heat Input
Orifice Size
Orifice
(Injector)
Quantity
Burner
Pressure
Btu/ft
3
in wc Btu/hr kW DMS mm in wc
Natural 1,000
7.0-13.0
40,000
11.72
30
3.264
1
3.0
*Liquid Propane 2,500
11.0
40,000
11.72
49
1.854
1
10.0
Shaded areas are stated in metric equivalents
* Gas valve’s internal regulator disabled.