D40 Installation Manual
Phase 7 / Fire Suppression System
JLA Limited
Meadowcroft Lane, Halifax Road
Ripponden
West Yorkshire, England
HX6 4AJ
Telephone: 01422 822282 / Fax: 01422 824390
WARNING: For your safety the information
in this manual must be followed to
minimize the risk of fire or explosion or to
prevent property damage, personal injury
or death.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your
building.
Clear the room, building or area of
all occupants.
Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
If you cannot reach your gas
supplier, call the fire department.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
AVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans cette
notice pour réduire au minimum le risque
d’incendie ou d’explosion ou pour éviter
tout dommage matériel, toute blessure ou
la mort.
Ne pas entreposer ni utiliser d’essence
ni d’autres vapeurs ou liquides
inflammables à proximité de cet
appareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE
ODEUR DE GAZ:
Ne pas tenter d’allumer d’appareils.
Ne touchez à aucun interrupteur.
Ne pas vous servir des téléphones
se trouvant dans le bâtiment.
Évacuez la pièce, le bâtiment ou la
zone.
Appelez immédiatement votre
fournisseur de gaz depuis un voisin.
Suivez les instructions du
fournisseur.
Si vous ne pouvez rejoindre le
fournisseur de gaz, appelez le
service des incendies.
L’installation et l’entretien doivent être
assurés par un installateur ou un service
d’entretien qualifié ou par le fournisseur
de gaz.
JLA Part No. 113242
Question and Answer IconNeed help?

Do you have a question about the JLA D40 and is the answer not in the manual?

Summary

Safety Precautions

What To Do If You Smell Gas

Steps to follow if a gas leak is detected, including immediate actions and contacting authorities.

Fire and Explosion Hazards

Warnings about flammable vapors, improper grounding, and disabling safety circuits.

Specifications

Dryer Dimensions and Capacities

Detailed physical and performance specifications including capacity, volume, and airflow.

Gas and Electric Service Requirements

Specifications for gas inlet, electrical voltage, heat input, and steam connections.

Installation Procedures

Unpacking and Setting Up

Instructions for removing packaging and preparing the dryer for placement.

Leveling and Location Requirements

Guidelines for proper dryer placement, floor leveling, and environmental considerations.

Dryer Enclosure Requirements

Specifications for clearances and materials for dryer enclosures.

Fresh Air Supply Requirements

Details on necessary air intake for proper dryer operation and combustion.

Exhaust Requirements

Guidelines for proper installation and sizing of exhaust ductwork for safety and efficiency.

Single Dryer Venting

Specific venting requirements for individual dryer installations.

Horizontal Venting

Maximum length and elbow considerations for horizontal exhaust duct runs.

Vertical Venting

Maximum length and elbow considerations for vertical exhaust duct runs.

Multiple Dryer (Common) Venting

Horizontal Venting for Multiple Dryers

Guidelines for common horizontal exhaust ducting for multiple dryers.

Vertical Venting for Multiple Dryers

Guidelines for common vertical exhaust ducting for multiple dryers.

Electrical Information

Electrical Requirements

Standards and precautions for electrical installation by qualified personnel.

Gas and Steam Models Electrical Service

Electrical service specifications for gas and steam dryer models.

Electric Models Only Electrical Service

Electrical service specifications for all-electric dryer models.

Grounding

Electrical Connections and Grounding

Procedures for proper electrical connections and grounding methods.

Single-Phase Wiring Connections

Wiring hookup details for single-phase gas and steam dryers.

Three-Phase Wiring Connections

Wiring hookup details for three-phase gas and steam dryers.

Gas Information

Gas Supply and Connections

Requirements and standards for connecting the gas supply to the dryer.

Technical Gas Data and Specifications

Manifold and in-line pressure specifications for natural and propane gas.

Steam Information

Steam Coil pH Level and Requirements

Guidelines for steam coil pH levels and operating pressure for optimal performance.

Steam Supply and Return Line Installation

Instructions for proper installation of steam supply and return lines.

Compressed Air Supply

Air Pressure Requirements

Recommended air pressure ranges for the pneumatic damper system.

Air Regulation and Connection

Information on air connection and the need for external regulation and filtration.

Steam Damper System Operation

Damper Operation and Adjustment

Explanation of the steam damper's function in heating and cool down modes.

Water Information

Water Connection Requirements

Specifications for water supply pipe size, pressure, and flexible hose connections.

Water Solenoid Valve and Bypass

Details on the water solenoid valve and optional manual bypass installation.

Preparation for Operation;Start-Up

Pre-Operation Checklist

Essential checks before operating the dryer, covering labels, voltage, gas type, and components.

Preoperational Tests

Gas Model Specific Tests

Initial start-up procedures and ignition system checks for gas dryers.

Gas and Electric Model Safety Checks

Functional checks of safety circuits like door switches, hi-limits, and sail switches.

Basket Coating Removal

Instructions for cleaning the protective coating from the dryer basket.

Preoperational Instructions for Coin Models

Steps for operating coin-operated dryers using the microprocessor controller.

Mechanical Coin Meter Operation

Procedures for using mechanical coin meters or slide coin meters.

Non-Coin Model Operation

Operating instructions for non-coin dryer models using LED displays.

Dual Timer Dryer Operation

Instructions for operating dual timer dryers and adjusting spin/dwell times.

Service;Parts Information

Service Requirements

Guidelines for qualified service technicians and contacting the reseller.

Ordering Replacement Parts

Information on how to purchase replacement parts from the reseller or manufacturer.

Warranty Information

Returning Warranty Cards

Instructions for completing and returning warranty cards for record-keeping.

Routine Maintenance

Cleaning Procedures

Schedule and methods for cleaning lint screens, lint chambers, and exhaust systems.

Adjustments and Inspections

Regular checks of bolts, connections, controls, and safety devices.

Lubrication Guidelines

Information on lubricating motor and tumbler bearings, though often permanently lubricated.

Lint Drawer Removal and Maintenance

Steps for removing and cleaning the lint drawer.

Data Label Information

Understanding Dryer Data Labels

Explanation of the information found on the dryer's data label for service and parts.

Procedure for Functional Check of Replacement Components

Microprocessor Controller Board Check

Steps to verify the functionality of the replacement microprocessor controller board.

Johnson Direct Spark Ignition (DSI) Controller

Theory of operation and diagnostic indicators for the DSI controller.

Manual Reset Burner Hi-limit Instructions

Phase 7 Hi-Limit Reset Procedure

How to reset the burner hi-limit thermostat for Phase 7 models.

Dual Timer Hi-Limit Reset

Procedure for resetting the burner hi-limit thermostat on dual timer models.

JLA D40 Specifications