TO DISPENSE FROM FUEL STATION
Before use, read and follow all safety instructions on page 2 of this user's manual.
1. Ensure fuel station is at a higher elevation than the receiving tank. Fuel is gravity dispensed
through the dispensing nozzle.
2. Attach the ground wire clip end to frame of the equipment receiving the fuel to create a bond.
Bonding will place both the fuel station and receiving equipment at the same static charge
potential.
3. Slowly open the ll cap's manual vent screw to release any internal pressure. After releasing
pressure, open ball valve by turning the handle clockwise. The ball valve handle should be in-line
with the valve body.
4. Place the dispensing nozzle into the receiving fuel tank. The dispensing nozzle must remain inside
the receiving tank during the entire ll process.
5. Remove the locking clip from the dispensing nozzle. Squeeze dispensing nozzle handle to begin
ow, release to stop. Monitor ow and liquid levels to prevent spills and overlling.
4
FOR SERVICE ASSISTANCE, CALL 800-433-0708 OR VISIT JOHNDOW.COM
ASSEMBLY INSTRUCTIONS
TO FILL FUEL STATION
Before use, read and follow all safety instructions on page 2 of this user's manual.
1. Remove ground screw [5] from tank [1] leg using screwdriver or nut driver. Assemble green
ground wire [4] to tank by placing screw through the connector and reattaching to tank leg.
Tighten securely using screwdriver or nut driver.
2. Assemble ll cap [6] onto ll neck. Make sure cap is secure by turning completely to stop position,
described in To Close for Transportation or Storage.
3. Wrap ½” tting on hose [2] with PTFE tape. Thread into ball valve. Tighten with wrenches.
4. Wrap ¾” ttings on hose [2] with PTFE tape. Thread nozzle [3] onto hose end. Tighten with
wrenches.
5. Afx the included GASOLINE UN 1203 [10] label to the fuel station, on a side visible during
transportation.
Before lling, read and follow all safety instructions on page 2 of this user's manual.
1. Alwayslayfuelstationonthegroundawayfromvehiclebeforellingtodissipateanystatic
charge.
2. Dissipate any static electricity from your body by touching a metal surface away from the service
station nozzle and prior to removing service station nozzle from dispensing pump.
3. Ensure the ball valve is closed. The ball valve handle should be in a 90° position to the valve
body, as described in To Close and Secure for Transportation and Storage.
4. Removellcapfromfuelstationandinsertservicestationnozzleintothellerneckopening.
5. Whilelling:
a. Do not remove service station nozzle from fuel station. Keep the service station nozzle in
contact with the rim of the fuel station at all times until fueling is complete.
b. Do not use service station nozzle lock-open device. Fill slowly to prevent the buildup of static
charge.Stopimmediatelyifyousensethebuildupofstaticcharge.Donotresumellinguntil
static charge dissipates.
c. Closelymonitorowtopreventspillsandoverlling.Donotllabovethebottomoftheller
neck.
6. Replacellcapandtightenassecurelyaspossiblebyhand,asdescribedinTo Close and
Secure for Transportation and Storage.
7. Wipe any gasoline residue from surface of fuel station or allow to evaporate. If fuel spills on
clothing, change clothing immediately.

Other manuals for JohnDow Industries JDI-FST15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JohnDow Industries JDI-FST15 and is the answer not in the manual?

JohnDow Industries JDI-FST15 Specifications

General IconGeneral
BrandJohnDow Industries
ModelJDI-FST15
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals