Nomenclature
3: Combined Pre and Post Filter Transducer
and Combined Magnehelic Gauge
4: Separate Pre and Post Filter Transducer
and Magnehelic Gauge
5: Combined Pre and Post Filter Magnehelic
Gauge
6:
Separate Pre and Post Filter Magnehelic
Gauge
7: Combined Pre and Post Filter Transducer,
Separate Pre and Post Filter Magnehelic
Gauge
Digit 15: Supply Fan
A: Direct Drive Plenum (DDP) Supply Fan with
1-inch Spring Isolation
B: DDP Supply Fan with 2-inch Spring Isolation
C: DDP Supply Fan with 2-inch Spring Isola-
tion and Seismic Restraint
Digit 16: Supply Fan Motor
Horsepower
A: 5 HP
B: 7.5 HP
C: 10 HP
Digit 17: Supply Fan Motor Type
2: ODP Premium Efficiency 1,800 RPM
4: TEFC Premium Efficiency 1,800 RPM
Digit 18: Supply Fan Options
0: None
1: Inlet Guard
2: Airflow Measurement Station
3: Shaft Grounding Ring
4: Inlet Guard and Airflow Measurement
Station
5: Inlet Guard and Shaft Grounding Ring
6: Airflow Measurement Station and Shaft
Grounding Ring
7: Shaft Grounding Ring, Inlet Guard and
Airflow Measurement Station
Digits 19: Building Pressure
Control
0: None
1: Barometric Damper
2: Exhaust with VFD and Backdraft Damper
3: Modulating Damper (On/Off Exhaust Fan
Only without VFD)
4:
Modulating Damper (Return Fan Only with
VFD)
Digit 20: Return/Exhaust Fan
A: None
B: Exhaust Fan with 1-inch Spring Isolation
C: Exhaust Fan with 2-inch Spring Isolation
D: Exhaust Fan with 2-inch Spring Isolation
and Seismic Restraint
E: Return Fan with 1-inch Spring Isolation
F: Return Fan with 2-inch Spring Isolation
G: Return Fan with 2-inch Spring Isolation and
Seismic Restraint
Digit 21: Return/Exhaust Fan
Motor Horsepower
A: None
E: 3 HP
F: 5 HP
G: 7.5 HP
H: 10 HP
J: 15 HP
K: 20 HP
Digit 22: Return/Exhaust Fan
Motor Type
0: None
2: ODP Premium Efficiency 1,800 RPM
4: TEFC Premium Efficiency 1,800 RPM
Digit 23: Return/Exhaust Fan
Options
A: None
B: Shaft Grounding Ring
C: Extended Grease Lines
D:
Extended Grease Lines and Shaft Ground-
ing Ring
E: Belt Guards
F: Belt Guards and Shaft Grounding Ring
G: Return Fan Airflow Measurement Station
H: Return Fan Airflow Measurement Station
and Shaft Grounding Ring
J: Extended Grease Lines and Belt Guards
K: Extended Grease Lines and Belt Guards
and Shaft Grounding Ring
L: Extended Grease Lines and Return Fan
Airflow Measurement Station
M: Extended Grease Lines and Return Fan
Airflow Measurement Station and Shaft
Grounding
N: Belt Guards and Return Fan Airflow Mea-
surement Station
P: Belt Guards and Return Fan Airflow
Measurement Station and Shaft Ground-
ing Ring
Q: Extended Grease Lines and Belt Guards
and Return Fan Airflow Measurement
Station
R: Extended Grease Lines and Belt Guards
and Return Fan Airflow Measurement
Station and Shaft Grounding Ring
Digits 24: Return/Exhaust Fan
Drive
A: None
B–K: RPM
Digit 25: Evaporator Options
G: Aluminum Fin Evaporator with SST Drain
Pan
H: Aluminum Fin Evaporator with SST Drain
Pan with Condensate Overflow Switch
J: E-Coat Aluminum Fin Evaporator with SST
Drain Pan
K: E-Coat Aluminum Fin Evaporator with
SST Drain Pan with Condensate Overflow
Switch
L: Copper Fin Evaporator with SST Drain Pan
M: Copper Fin Evaporator with SST Drain
Pan with Condensate Overflow Switch
Digit 26: Condenser Coil Options
2: With Wire Guards
3: Full Louvered Panels
4: Partial Louvered Panels with Wire Guards
6: E-Coat Condenser with Wire Guards
7: E-Coat Condenser, Full Louvered Panels
8: E-Coat Condenser, Partial Louvered
Panels with Wire Guards
Digit 27: Draw-Thru Filter Options
A: Angled Filter Rack, No Filters
B: Angled Filter Rack, 2-Inch Throwaway
Filters
C: Angled Filter Rack, 2-Inch MERV 8 Filters
D: Rigid Filter Rack, No Filters
E: Rigid Filter Rack, MERV 15 Bag Filters
with 2-Inch MERV 8 Pre-Filters
F: Rigid Filter Rack, MERV 14 Rigid Filters
with 2-Inch MERV 8 Pre-Filters
G: Vertical Filter Rack, No Filters
H: Vertical Filter Rack, 4-Inch MERV 8 Filters
Digit 28: Draw-Thru Filter Control
Options
0: None
1: Combined Pre and Post Filter Transducer
2: Separate Pre and Post Filter Transducer
3: Combined Pre and Post Filter Transducer
and Combined Magnehelic Gauge
4: Separate Pre and Post Filter Transducer
and Magnehelic Gauge
5: Combined Pre and Post Filter Magnehelic
Gauge
6:
Separate Pre and Post Filter Magnehelic
Gauge
7: Combined Pre and Post Filter Transducer,
Separate Pre and Post Filter Magnehelic
Gauge
Digit 29: Economizer Options
A: None
C: Dry Bulb Economizer, Low Leak Dampers
D: Single Enthalpy Economizer, Low Leak
Dampers
E:
Dual Enthalpy Economizer, Low Leak
Dampers
F: Dry Bulb Economizer, Low Leak Dampers
with Airflow Measurement Station
G: Single Enthalpy Economizer, Low Leak
Dampers with Airflow Measurement Station
H: Dual Enthalpy Economizer, Low Leak
Dampers with Airflow Measurement Station
K: Dry Bulb Economizer, Ultra Low Leak
Dampers
L: Single Enthalpy Economizer, Ultra Low
Leak Dampers
S: Dual Enthalpy Economizer, Ultra Low Leak
Dampers
T: Dry Bulb Economizer, Ultra Low Leak
Dampers with Airflow Measurement Station
U: Single Enthalpy Economizer, Ultra Low
Leak Dampers with Airflow Measurement
Station
V: Dual Enthalpy Economizer, Ultra Low
Leak Dampers with Airflow Measurement
Station
Digit 30: Energy Recovery
Options
0: None
1: Low CFM Energy Recovery Wheel (ERW)
without VFD
2: Low CFM ERW with VFD
3: High CFM ERW without VFD
4: High CFM ERW with VFD
Digit 31: Refrigeration System
Piping Options
A: None
B: Suction and Discharge Valves
C: Suction, Discharge, and Liquid Valves
D: Suction, Discharge, and Liquid Valves with
Replaceable Core Filter Driers
E: Hot Gas Reheat (HGRH)
F: Suction and Discharge Valves with HGRH
G: Suction, Discharge, and Liquid Valves with
HGRH
D: 15 HP
E: 20 HP
F: 25 HP
G: 30 HP
H: 40 HP
J: 50 HP

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls GVD Series and is the answer not in the manual?

Johnson Controls GVD Series Specifications

General IconGeneral
BrandJohnson Controls
ModelGVD Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals