DESCRIPTION
These packaged cooling air conditioners are designed for
outdoor installation. Only utility and duct connections are
required at the point of installation.
Field-installed electric heater accessories are available to
provide electric heat combined with electric cooling.
STANDARD FEATURES / BENEFITS
OPERATING EFFICIENCY - All ACP units provide high
operating efficiencies and have a SEER up to 13.
ON SITE FLEXIBILITY - All model sizes share a common,
compact design cabinet with a single footprint. The installer has
the flexibility of setting one curb and placing the proper tonnage
unit on that curb after the internal load has been determined.
Field convertible duct connections from side shot to down shot
allows the installer to have greater flexibility and needs to carry
less inventory.
LOWER INSTALLATION COST - Installation time and costs
are reduced by easy power and control wiring connections. The
small base dimension means less space is required on the
ground or roof, plus, the installer can fit this unit between the
wheel wells of a full size pick-up truck. All models are well under
500 pounds.
All units are completely wired, charged with R-22 and tested
prior to shipment. Unique test stations using a new state of the
art computerized process system are used to insure product
quality. Refrigerant charge, and component part numbers are
verified via computers at installation. Vital run test statistics
such as system pressure, motor currents, air velocity and
temperature and unit vibration are monitored and recorded by
the system to insure unit performance.
Equal size, side supply and return duct connections allows easy
hook-up of ducts to match low crawl spaces without transition
pieces.
SINGLE PACKAGE
COOLING UNITS
ACP024 THRU 060
2 THRU 5 TON (13 SEER)
ISO 9001
Certified Quality
Management System
Question and Answer IconNeed help?

Do you have a question about the Johnson Controls ACPU024 THRU 060 and is the answer not in the manual?

Johnson Controls ACPU024 THRU 060 Specifications

General IconGeneral
ModelACPU024 THRU 060
RefrigerantR-410A
Phase1
Compressor TypeScroll
Cooling Capacity24, 000 - 60, 000 BTU/h (depending on the specific model)
Voltage208/230V
Dimensions (H x W x D)Varies depending on specific model. Refer to specific model's documentation.
WeightVaries depending on specific model. Refer to specific model's documentation.

Summary

Technical Guide: Single Package Cooling Units

Product Description

Overview of single package cooling units designed for outdoor installation.

Standard Features and Benefits

Highlights operating efficiency, flexibility, and lower installation costs.

Unit Features and Construction

Technical Data Summary

ARI Ratings

Table presenting cooling capacity, SEER, sound ratings, and electric heat capacities.

Wiring Diagrams

Control Wiring Diagram

Illustrates thermostat and unit terminal strip wiring for control circuits.

Power Wiring Diagram

Shows single and three-phase power supply hookups, including disconnects.

Wiring Diagrams - 208/230-1-60

Wiring Diagrams - 208/230-3-60

Wiring Diagrams - 460-3-60

Typical Wiring Diagram

Detailed schematic for three-phase 460V power supply and electric heat.

Mechanical Specifications

General Description and Unit Cabinet

Unit assembly, cabinet construction, materials, and design features.

Fan Assemblies and Refrigerant Systems

Details indoor/outdoor fan systems and refrigerant circuit components.

Operational and Electrical Requirements