FEATURES
1-22
TC-15001-rev.3
Ŷ :D\&DVVHWWH7\SH0RGHOV
+<,&%6WR+<,&%6
Ɣ)OH[LEOH'HVLJQ
(1) Ability to choose from three installation types
• Corner Type (Standard)
It is possible to install the unit closer to the wall side of the
ceiling.
No interference with ceiling equipment such as lighting, and
assists in providing additional space for ceiling equipment.
&OLSSHG&HLOLQJIRU:D\'LVFKDUJH7\SH2SWLRQDO
It is suitable if requirements are not to embed the unit directly
into the ceiling because of ceiling equipment.
&OLSSHG&HLOLQJIRU:D\'LVFKDUJH7\SH2SWLRQDO
'LVFKDUJHGDLULVGLVFKDUJHGKRUL]RQWDOO\IURPWKHIURQWDLU
outlet and downward from the lower air outlet for wide air
distribution.
 )OH[LELOLW\RILQVWDOODWLRQRQDKLJKFHLOLQJ
,IWKHXQLWLVLQVWDOOHGRQDKLJKFHLOLQJXVHWKHKLJKVSHHGIXQFWLRQWRVHOHFWWKHDLUÀRZYROXPHZKLFK
is higher than the QRUPDODLUÀRZYROXPH
6HW+LJK6SHHGXVLQJWKHZLUHGFRQWUROOHUGHSHQGLQJRQWKHFHLOLQJKHLJKWDVVKRZQLQWKHWDEOH
below.
Ɣ 6OLPDQG6W\OLVK'HVLJQ
7KHXQLWKHLJKWLVRQO\LQFKHVPP
It can be installed at a small installation height such as a clipped
ceiling.
'HFRUDWLYHSDQHOGHVLJQLVVLPSOHDQGVW\OLVK
The shutter function closes the air outlet with the louver when
the operation is stopped.
Ɣ +LJKO\$GYDQFHG/RZ6RXQG3UHVVXUH/HYHO
By improving the fan wing shape and air outlet design, there is
KLJKO\LPSURYHGHI¿FLHQF\RIWKHDLUÀRZRSHUDWLRQDQGORZHUVRXQG
pressure level.
127(
1RWVXLWDEOHIRULQVWDOOLQJRQDKLJKFHLOLQJDVWKHKHDWHGDLUKDVGLI¿FXOW\UHDFKLQJWKHÀRRU
127(
$VIRU:D\'LVFKDUJH7\SHDLUUHDFKLQJGLVWDQFHLVVKRUWHUWKDQ:D\'LVFKDUJHG7\SH
When installing, make sure that ceiling height is within 8.9 ft. (2.7m)
&HLOLQJ+HLJKW
+LJK6SHHG
Setting Function
+<,&%6
+<,&%6
+<,&%6
+<,&%6
/HVVWKDQIWP /HVVWKDQIWP Standard
9 ft. to 10 ft. (2.7 - 3.0m) 10 ft. to 12 ft. (3.1 - 3.5m) +LJK6SHHG
Fan Casing
Fan Runner

Table of Contents

Other manuals for Johnson Controls (H,Y,C)IDM012B21S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls (H,Y,C)IDM012B21S and is the answer not in the manual?

Johnson Controls (H,Y,C)IDM012B21S Specifications

General IconGeneral
BrandJohnson Controls
Model(H, Y, C)IDM012B21S
CategoryAir Conditioner
LanguageEnglish

Related product manuals