Note: Some network engines are also available in
a Buy American version (add a G after the product
code number). For the European version, add an
E after the product code number. For repair parts,
specify 703 in place of the last digit of the product
code number.
Table 22: NAE55-3 ordering information (Release 8.1 or 11.0)
Product Code Number Release Description
MS-NAE55xx-x (Base
Features of Each NAE55)
N/A
NAE55 Network Automation Engines: Requires a 24 VAC power supply. Each
model includes two RS-232-C serial ports, two USB serial ports, two RS-485
ports, one Ethernet port, and one MS-BAT1010-0 Data Protection Battery.
Supports a BACnet IP network.
MS-NAE5510-3 11.0
Supports two third-party trunks (Modbus RTU or TCP, M-Bus, or KNX) and two
N2 or two BACnet MS/TP (RS-485) trunks (or one N2 trunk and one BACnet
MS/TP trunk). Supports up to 100 devices on each N2 or BACnet MS/TP trunk.
This model is a BACnet BTL-Listed controller at Protocol Revision 15 (PR15).
MS-NAE5510-3U
11
8.1
Supports two N2 Bus or two BACnet MS/TP (RS-485) trunks (or one N2 Bus
trunk and one BACnet MS/TP trunk).
Note: This model is UL 864 10th Edition UUKL/ORD-C100-13 UUKLC
Standard for Smoke Control Equipment for Release 8.1 only. Refer to
the Metasys
®
System UL 864 10th Edition UUKL/ORD-C100-13 UUKLC Smoke
Control System Technical Bulletin (LIT-12012487) for detailed specifications,
requirements, and procedures for installing and operating UUKL 864
Listed Metasys system devices. For example, in order to be UL/cUL
compliant, this model must be pre-installed and pre-wired in a standard
or custom panel built at the Johnson Controls Reynosa factory.
MS-NAE5511-3 11.0
Supports two third-party trunks (Modbus RTU or TCP, M-Bus, or KNX) and two
N2 or two BACnet MS/TP (RS-485) trunks (or one N2 trunk and one BACnet
MS/TP trunk); includes an internal modem. Supports up to 100 devices on
each N2 or BACnet MS/TP trunk. This model is a BACnet BTL-Listed controller
at Protocol Revision 15 (PR15).
Note: Modem functions are no longer available after this engine is
updated with Metasys Release 10.0 or later.
MS-NAE5520-3 11.0
Supports a LonWorks trunk, two third-party trunks (Modbus RTU or TCP, M-
Bus, or KNX), or two N2 trunks/BACnet MS/TP (RS-485) trunks (or one N2 trunk
and one BACnet MS/TP trunk). Supports up to 255 devices on the LonWorks
trunk. Supports up to 100 devices on each N2 or BACnet MS/TP trunk. This
model is a BACnet BTL-Listed controller at Protocol Revision 15 (PR15).
MS-NAE5521-3 11.0
Supports a LonWorks trunk, two third-party trunks (Modbus RTU or TCP, M-
Bus, or KNX), or two N2 trunks/BACnet MS/TP (RS-485) trunks (or one N2 trunk
and one BACnet MS/TP trunk); includes an internal modem. Supports up to
255 devices on the LonWorks trunk. Supports up to 100 devices on each N2 or
BACnet MS/TP trunk. This model is a BACnet BTL-Listed controller at Protocol
Revision 15 (PR15).
Note: Modem functions are no longer available after this engine is
updated with Metasys Release 10.0 or later.
1 The older MS-NAE5510-2U model may also be available.
NAE55 Installation Guide20