Technical Bulletin Network Room Module
Issue Date January 22, 2010
© 2010 Johnson Controls, Inc.
Code No. LIT-12011258
Network Room Module
Introduction to Network Room Module (NRM).....................................3
Concepts.............................................................................................................. 4
Features............................................................................................................................. 4
Controls..............................................................................................................................5
Functions and Setup of the Network Room Module........................................................... 6
Network Room Module Parameters (Room Sensor Object) ............................................ 13
Installing and Commissioning the Network Room Module..............15
Introduction........................................................................................................ 15
North American Emissions Compliance........................................................................... 15
Key Concepts..................................................................................................... 16
Location of the Network Room Module............................................................................ 16
Dimensions of the Network Room Module....................................................................... 17
Wiring...............................................................................................................................18
Addressing ....................................................................................................................... 19
Service Port...................................................................................................................... 20
Commissioning the Network Room Module..................................................................... 22
Procedure Overview......................................................................................................... 23
Detailed Procedures.......................................................................................... 23
Opening the Network Room Module................................................................................ 23
Mounting the NRM Directly on a Wall Surface................................................................. 24
Mounting the NRM (80 x 80 mm) on a Wall Surface Using the
Plastic Base for Surface Mounting................................................................................... 26
Mounting the NRM (80 x 80 mm) on a Recessed Wall Box............................................. 27
Commissioning the NRM Module..................................................................................... 29

Questions and Answers

  • B
    Bobby ChaseJul 28, 2025
    Why is the maintenance icon showing on my Johnson Controls Network Hardware?
    • S
      Steven DominguezJul 28, 2025
      The maintenance icon appears for several reasons: a failed PT1000 temperature sensor in the NRM (replace the NRM module), a communication problem with the FX controller (check the bus wiring to the display and ensure the +, - and COM wires are correctly connected), or an off-normal condition reported by the controller.
  • D
    Douglas JonesAug 2, 2025
    What to do if Johnson Controls Network Hardware display shows different setpoint values than the FX controller?
    • K
      Katrina McguireAug 2, 2025
      First, verify that the controller to which the NRM module is connected has been loaded with the correct configuration and that the configuration properties have been set correctly. Then, use the FX CommPro Commissioning Tool to check that the value of the relevant network variable output of the Room Sensor object matches the value on the LCD. If not, replace the NRM module.
  • S
    Sandra AndrewsAug 7, 2025
    How to fix a manual change that doesn't work as expected on Johnson Controls Network Hardware?
    • T
      Timothy BranchAug 7, 2025
      Verify that the configuration properties to enable the command are set correctly. Using the FX CommPro Commissioning Tool, check that the values of the network variable outputs from the Room Sensor object respond in accordance with the display changes as the dial is rotated or the fan push button is pressed. Also, verify that the controller to which the NRM module is connected has been loaded with the correct configuration.
  • B
    brent59Aug 12, 2025
    What to do if NRM shows fan override status, but it's not active in Johnson Controls Network Hardware controller?
    • A
      Alyssa RiceAug 12, 2025
      Verify that the controller to which the NRM module is connected has been loaded with the correct configuration and that the configuration is designed to react correctly to an override status. Check for other conditions that could override the NRM module override.
  • N
    nelsonsamuelAug 17, 2025
    Why is a symbol not appearing as expected on my Johnson Controls Network Hardware display?
    • R
      Ryan ValenciaAug 17, 2025
      Verify that the configuration properties to enable the display of the symbol are set correctly in the Room Sensor object in the FX controller. Also, verify that the FX controller to which the NRM module is connected has been loaded with the correct configuration.
  • K
    Kimberly HarrisonAug 22, 2025
    How to troubleshoot a Johnson Controls Network Hardware LCD with no display?
    • P
      Patricia MayoAug 22, 2025
      The most likely cause is a lack of power. Check the wiring and supply voltage to the module.

Summary

Introduction to Network Room Module (NRM)

Network Room Module Parameters (Room Sensor Object)

Lists and defines the configurable parameters for the NRM in the Room Sensor object.

Installing and Commissioning the Network Room Module

Wiring

Explains the electrical connections and terminal block layout for the NRM.

Addressing

Covers how to set the physical address for addressable NRM models.

Commissioning the Network Room Module

Details the process of setting up and verifying the NRM's operation.

Commissioning the NRM Module

Final steps to verify and activate the NRM's functionality.

Troubleshooting

Troubleshooting NRM Installation

Addresses common issues encountered during NRM installation and operation.

Johnson Controls Facility Explorer Specifications

General IconGeneral
ConnectivityEthernet, RS-485
Communication ProtocolsBACnet/IP, BACnet MS/TP, N2
Operating Temperature32°F to 122°F (0°C to 50°C)
Power Supply24 VAC/VDC
SeriesFX
Communication Speed9.6 kbps to 76.8 kbps (MS/TP)
DimensionsVaries by model
WeightVaries by model
Humidity Rangenon-condensing

Related product manuals