Performance data - 3.5 ton
See the following tables for performance and multiplier data for the RAC13442B21S unit.
Condenser only performance data - 3.5 ton
Table 32: Condenser only performance data - 3.5 ton
Saturated suction
at compressor
Outdoor ambient temperature
Temperature Pressure 55°F 65°F 75°F 85°F 95°F 105°F 115°F
(°F) (psig) MBH kW MBH kW MBH kW MBH kW MBH kW MBH kW MBH kW
35 107 40.8 1.87 38.8 2.02 36.6 2.23 34.4 2.49 31.9 2.80 29.4 3.17 26.7 3.59
40 118 44.8 1.87 42.6 2.02 40.2 2.23 37.7 2.49 35.2 2.81 32.5 3.18 29.7 3.60
45 130 49.0 1.86 46.5 2.02 43.9 2.23 41.2 2.50 38.5 2.82 35.6 3.19 32.6 3.61
50 142 53.3 1.86 50.5 2.02 47.7 2.23 44.8 2.51 41.9 2.83 38.8 3.21 35.7 3.63
55 156 57.7 1.85 54.6 2.02 51.6 2.24 48.5 2.52 45.3 2.85 42.1 3.23 38.8 3.66
Condenser only performance data notes
For outdoor unit (condenser) performance only. Data does not include the effects of air handler
power or heat.
Performance based on 15°F subcooling and 15°F superheat at the outdoor unit base valves:
a. Increase capacity by 1% for each 2°F increase in subcooling.
b. Decrease capacity by 1% for each 2°F decrease in subcooling.
Maximum recommended condensing temperature is 140°F.
Cooling performance data - 3.5 ton
Table 33: Cooling performance data - 3.5 ton - indoor coil: XAFC42EXXN1
IDCFM 1200 1400 1600
ID DB
(°F)
80 80 75 80 80 80 80 75 80 80 80 80 75 80 80
Air
temperature
entering
outdoor unit
(°F)
ID WB
(°F)
57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
T.C. 40.2 42.0 41.5 46.3 46.4 42.1 43.1 42.6 46.9 47.7 44.0 44.2 43.8 47.4 48.9
S.C. 40.2 37.2 31.7 32.3 24.6 42.1 40.1 33.6 33.7 26.0 44.0 43.1 35.6 35.2 27.3
55
kW 2.31 2.30 2.30 2.26 2.23 2.38 2.37 2.38 2.34 2.31 2.45 2.44 2.45 2.41 2.39
T.C. 39.0 40.4 39.8 43.7 45.5 40.7 41.7 41.1 44.7 46.5 42.5 43.0 42.3 45.6 47.4
S.C. 39.0 36.6 30.7 31.1 23.9 40.7 39.5 32.9 33.1 25.4 42.5 42.5 35.1 35.0 26.9
65
kW 2.58 2.58 2.58 2.55 2.51 2.66 2.65 2.66 2.62 2.59 2.73 2.73 2.74 2.70 2.68
T.C. 37.7 38.7 38.1 41.2 44.6 39.3 40.3 39.5 42.5 45.3 40.9 41.8 40.9 43.8 45.9
S.C. 37.7 35.9 29.8 30.0 23.2 39.3 38.9 32.2 32.4 24.8 40.9 41.8 34.6 34.8 26.4
75
kW 2.85 2.85 2.86 2.83 2.79 2.93 2.93 2.94 2.91 2.88 3.01 3.01 3.02 2.99 2.96
T.C. 36.3 37.6 36.9 40.1 42.8 37.8 38.6 38.0 41.3 43.6 39.4 39.7 39.2 42.4 44.4
S.C. 36.3 35.5 29.3 29.6 22.7 37.8 37.7 31.6 31.9 24.3 39.4 39.7 33.9 34.2 25.9
85
kW 3.15 3.16 3.16 3.15 3.13 3.23 3.24 3.25 3.23 3.21 3.32 3.32 3.33 3.32 3.30
T.C. 34.8 36.4 35.6 39.0 41.0 36.3 37.0 36.5 40.0 41.9 37.8 37.5 37.4 41.0 42.9
S.C. 34.8 35.0 28.9 29.2 22.3 36.3 36.5 31.1 31.4 23.8 37.8 37.5 33.3 33.6 25.4
95
kW 3.45 3.47 3.47 3.47 3.46 3.54 3.55 3.56 3.56 3.55 3.62 3.63 3.65 3.64 3.64
T.C. 32.9 33.7 32.8 36.2 38.4 34.3 34.5 33.6 37.2 39.1 35.7 35.3 34.5 38.2 39.8
S.C. 32.9 32.9 27.5 27.9 21.4 34.3 34.3 29.6 30.1 22.9 35.7 35.3 31.8 32.4 24.3
105
kW 3.91 3.93 3.96 3.93 3.89 3.99 4.00 4.04 4.00 3.97 4.06 4.07 4.12 4.08 4.06