415571-UTG-C-0309
10 Johnson Controls Unitary Products
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. TCGD36S4(3,4)S1
INDOOR COIL MODEL NO. FC/MC/PC43
CONDENSING
ENTERING AIR
TEMPERATURE
IDCFM 1000 1200 1400
ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80
ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
65
T.C. 34.7 36.1 35.2 37.4 37.3 33.8 35.5 34.8 37.0 37.5 32.9 34.9 34.4 36.6 37.6
S.C. 34.3 33.0 27.6 25.5 18.4 33.3 31.0 26.2 24.6 18.0 32.3 29.1 24.7 23.6 17.7
KW 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 1.9 2.0 1.9 2.0 2.0
75
T.C. 33.6 34.7 33.6 35.9 36.6 32.6 33.9 33.2 35.5 36.6 31.5 33.2 32.7 35.1 36.6
S.C. 33.3 32.5 27.5 25.6 18.6 32.1 30.6 25.8 24.5 18.0 31.0 28.7 24.2 23.3 17.5
KW 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.1 2.2 2.2 2.2 2.2
85
T.C. 32.4 33.2 32.0 34.4 35.8 31.3 32.3 31.5 34.1 35.7 30.2 31.5 31.0 33.7 35.5
S.C. 32.2 32.0 27.3 25.8 18.8 30.9 30.2 25.5 24.3 18.0 29.6 28.3 23.7 22.9 17.3
KW 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.3 2.4 2.4 2.4 2.4
95
T.C. 31.3 31.7 30.4 33.0 35.0 30.1 30.7 29.9 35.0 34.8 28.9 29.8 29.4 32.2 34.5
S.C. 31.1 31.5 27.2 26.0 19.0 29.7 29.7 25.2 24.9 18.0 28.3 27.9 23.2 22.5 17.1
KW 2.6 2.6 2.6 2.6 2.7 2.6 2.6 2.6 2.6 2.7 2.5 2.6 2.6 2.6 2.6
105
T.C. 27.9 28.8 27.2 29.8 32.5 27.0 27.8 26.6 29.4 32.2 26.0 26.9 25.9 29.0 31.9
S.C. 28.7 28.9 25.0 25.0 18.4 27.3 27.2 23.2 23.2 17.3 25.8 25.6 21.5 21.4 16.2
KW 2.8 2.8 2.8 2.8 2.9 2.8 2.8 2.8 2.8 2.9 2.7 2.8 2.7 2.8 2.9
115
T.C. 24.6 26.0 24.2 26.8 30.1 23.9 25.1 23.4 26.3 29.8 23.3 24.1 22.6 25.9 29.5
S.C. 26.3 26.3 22.8 24.1 17.8 24.9 24.8 21.3 22.2 16.6 23.5 23.3 19.8 20.3 15.4
KW 3.0 3.0 3.0 3.0 3.1 3.0 3.0 2.9 3.0 3.1 2.9 2.9 2.9 3.0 3.1
125
T.C. 21.3 23.2 21.1 23.7 27.6 20.9 22.3 20.2 23.2 27.3 20.5 21.3 19.3 22.7 27.0
S.C. 23.9 23.8 20.6 23.2 17.2 22.5 22.4 19.4 21.2 15.9 21.1 21.0 18.2 19.2 14.6
KW 3.2 3.2 3.2 3.2 3.4 3.2 3.2 3.1 3.2 3.3 3.1 3.1 3.1 3.2 3.3
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handlers Coils T.C. S.C. KW
– FC/MC/PC43 1.00 1.00 1.00
– FC/MC/PC48 1.00 1.00 1.00
– HC42 1.00 1.00 1.00
– UC48 1.00 1.00 1.00
AHP36 – 1.00 1.00 1.00
AHP42 – 1.00 1.00 1.00
AHX36 – 1.01 1.01 0.96
AHX42 – 1.01 1.02 0.94
MA12B FC/MC43B 1.00 1.00 1.00
MA14D FC/MC48D 1.00 1.00 1.00
F5FP048 – 1.00 1.00 1.00
F6FP042 – 1.02 1.04 0.98
Furnaces Coils T.C. S.C. KW
T*(8,L)X*A12 FC/MC/PC37A 1.01 1.02 0.98
T*(8,L)X*B12 FC/MC/PC43B 1.01 1.02 0.98
T*(8,L)X*C16 FC/MC/PC43C 1.01 1.00 0.96
T*(8,L)X*C20 FC/MC/PC43C 1.02 1.03 0.96
T*9X*B12 FC/MC/PC43B 1.01 1.02 0.98
T*9X*C16 FC/MC/PC43C 1.01 1.02 0.98
T*9X*C20 FC/MC/PC43C 1.00 0.99 0.96
T*(8,L)X*C16 FC/MC/PC48C 1.02 1.02 0.97
T*(8,L)X*C20 FC/MC/PC48C 1.02 1.04 0.98
T*9X*C16 FC/MC/PC48C 1.02 1.04 0.98
T*9X*C20 FC/MC/PC48C 1.01 1.01 0.97
T*9X*D20 FC/MC/PC48D 1.01 1.01 0.97
T*(8,L)X*C16 UC48C 0.98 1.00 0.93
T*(8,L)X*C20 UC48C 0.99 1.02 0.95
T*9X*C16 UC48C 0.99 1.00 0.97
T*9X*C20 UC48C 0.97 0.99 0.95
T*9X*D20 UC48D 0.97 0.99 0.95