KP-241 PG2 Installation Instructions 5
Enrolling proximity tags
You can use proximity tags instead of user codes to arm and disarm the system. A proximity tag can be assigned to each of the
users 1 to 8.
1 Enter the Installer menu and select 02: ZONES/DEVICES.
2 Select ADD NEW DEVICES. The display reads ENROLL NOW or ENTR ID: xxx-xxxx.
3 Press the Arm Away button on the keypad. The Arm Away button blinks.
4 Present the proximity tag to the tag reader area of the keypad within the timeout period. If the tag enrols successfully, a
success tune sounds and the control panel displays DEVICE ENROLLED.
5 Optional: To assign the tag to another user, for example, User No. 5, enter 05, or press the forward button until the display
reads T05: Tag (Prox).
6 Press OK to confirm.
Mounting the keypad Figure 3: Mounting the keypad
1 Drill three holes in the mounting surface.
2 Insert the wall anchors and fasten the bracket with three screws.
3 Slide the keypad into the bracket.
4 Tighten the locking screw to secure the keypad to the bracket.