P5417009
Models:
Outdoor Units;
208/230V
(H,Y)VAHR072B32S, (H,Y)VAHR096B32S,
(H,Y)VAHR120B32S, (H,Y)VAHR144B32S,
(H,Y)VAHR168B32S, (H,Y)VAHR192B32S,
(H,Y)VAHR216B32S, (H,Y)VAHR240B32S,
(H,Y)VAHR264B32S, (H,Y)VAHR288B32S,
(H,Y)VAHR312B32S, (H,Y)VAHR336B32S,
(H,Y)VAHR360B32S, (H,Y)VAHR384B32S,
(H,Y)VAHR408B32S, (H,Y)VAHR432B32S
460V
(H,Y)VAHR072B42S, (H,Y)VAHR096B42S,
(H,Y)VAHR120B42S, (H,Y)VAHR144B42S,
(H,Y)VAHR168B42S, (H,Y)VAHR192B42S,
(H,Y)VAHR216B42S, (H,Y)VAHR240B42S,
(H,Y)VAHR264B42S, (H,Y)VAHR288B42S,
(H,Y)VAHR312B42S, (H,Y)VAHR336B42S,
(H,Y)VAHR360B42S, (H,Y)VAHR384B42S,
(H,Y)VAHR408B42S, (H,Y)VAHR432B42S
IMPORTANT:
READ AND UNDERSTAND
THIS MANUAL BEFORE
INSTALLING THIS HEAT
RECOVERY AIR CONDITIONER.
KEEP THIS MANUAL FOR
FUTURE REFERENCE.
Installation
and
Maintenance
Manual
INVERTER-DRIVEN
MULTI-SPLIT SYSTEM
HEAT RECOVERY
AIR CONDITIONERS
Question and Answer IconNeed help?

Do you have a question about the Johnson Controls YVAHR120B42S and is the answer not in the manual?

Johnson Controls YVAHR120B42S Specifications

General IconGeneral
BrandJohnson Controls
ModelYVAHR120B42S
CategoryAir Conditioner
LanguageEnglish

Summary

Important Safety Instructions

Signal Words and General Precautions

Defines hazard communication terms and outlines general safety guidelines for installation.

Installation Precautions

Location Selection and Hazardous Site Avoidance

Advises on selecting installation sites and avoiding hazardous locations.

Refrigerant Precautions

Safety Standards, Piping, and Contamination Prevention

Covers refrigerant safety standards, piping requirements, and preventing contamination.

Electrical Precautions

High Voltage, Wiring, Cables, and External Equipment

Details safety for high voltages, wiring, cable specs, and interaction with external equipment.

Electrical Installation Requirements

Circuit Breakers, Grounding, GFCI, and Installer Responsibility

Covers requirements for breakers, grounding, GFCI, and installer's code compliance responsibility.

Flaring and Joint

Flaring, Joint Selection, and Piping Material Specifications

Details flaring dimensions, joint selection criteria, and piping thickness/material requirements.

Combinations of Indoor and Outdoor Units

System Combination Conditions

Caution About Outdoor Unit Installation

Piping Work Between Outdoor Units

Outdoor Unit Installation

Location, Precautions, Foundation, and Drainage

Covers site selection, avoiding hazards, foundation requirements, and drainage during heating/defrost.

Installation Work

Concrete Foundation Requirements and Anchor Bolt Details

Details requirements for concrete foundations, including anchor bolt placement and foundation design.

Refrigerant Piping Work

Pressure, Thickness, Stop Valve Checks, and Pipe Connections

Covers R410A pressure requirements, piping thickness, stop valve checks, and basic pipe connections.

Piping Connection Work

Piping Size and Multi-Kit Selection

Piping Work Conditions and Limitations for Combined Systems

Piping Branch Restriction

Electrical Wiring

Electrical Wiring Safety and Precautions

Covers safety warnings, cable specs, torque, and DIP switch settings for electrical connections.

Electrical Wiring Connection Procedures

Details power supply wiring to outdoor and indoor units, and communication cable connections.

Outdoor Unit Electrical Wiring Connections

Details connecting power, ground, and communication cables to the outdoor unit, including torque specs.

System-Wide Electrical Wiring Connections

Covers power supply wiring for indoor units and change-over boxes, and communication cable connections.

Additional Refrigerant Charge

Airtight Test Procedures and Leak Detection

Explains how to perform an airtight test using nitrogen gas and leak detection methods.

Vacuuming Procedures for Refrigerant System

Details the triple evacuation method for vacuum drying the refrigerant system.

Refrigerant Charging Procedures and Stop Valve Cautions

Covers refrigerant charging steps, stop valve handling, and torque specifications.

Calculating Additional Refrigerant Charge

Provides methods and formulas for calculating the total additional refrigerant charge based on various system components.

Test Run

Pre-Test Run Checks and Preparations

Details checks for piping, communication lines, electrical resistance, voltage, and compressor pre-heating.

Insulation Resistance Caution and Pre-Test Checks

Addresses insulation resistance issues and confirms pre-test checks before proceeding.

Performing the Test Run via Wired Controller

Guides users on how to initiate and conduct the test run using the wired controller and its interface.

Safety and Control Device Setting

Compressor Protection Mechanisms Overview

Explains compressor protection via high pressure switches and oil heaters.