LED screen Possible faults Possible steps
LED 4 is green Battery pack is
overcharged
Remove the battery pack from the battery charger and install in
the product. Operate the product. Battery charger may be de-
fective. Speak to an approved service center.
LED 1 is red and LED 2 is
green, battery pack does not
charge or operate correctly in
product
Battery pack failure Remove battery pack from the product. Do not charge. Battery
pack is damaged and must be replaced. Speak to an approved
service center.
RED LED comes on, LED 2
is green and flashes during
charging or when the battery
pack is in the battery charger
Internal battery
tempature is too
low or too high for
charging
Move the battery charger and battery pack to a location where
the internal temperature of the battery pack can be between
5°C (41°F) and 45°C (113°F).
RED LED flashes and LED 2
flashes green when the bat-
tery pack is installed.
Internal battery
temperature is too
low or too high
The internal temperature in the battery must be between -15°C
(5°F) and 70°C (158°F). The environment temperature in the
battery pack is too low or too high.
•
If the battery pack is too cold from the ambient environ-
ment, move the battery pack and battery charger to a warm
environment.
•
If the battery pack is too hot, especially after operation,
move the battery pack and battery charger away from the
hot environment.
TECHNISCHE DATEN
Einheit HT2258 Li (BHT58VJN)
Motorspezifikationen
Motortyp Bürstenlos
Motorspannung V (DC) 58
Motorleistung Mi 400
Spezifikationen für Akku und Ladegerät
Standard-Akkutyp 140Li
Standard-Ladegerättyp 275Ci
Lärm- und Vibrationsdaten
Äquivalenter Vibrationspegel (ahv, eq) Handgriff
vorn. Siehe Anmerkung 1.
m/s
2
2,497
Äquivalenter Vibrationspegel (ahv, eq) Handgriff
rechts. Siehe Anmerkung 1.
m/s
2
2,884
Schallleistungspegel, garantiert (LWA). Siehe An-
merkung 2.
dB(A) 96
Gemessener Schallleistungspegel. Siehe Anmer-
kung 2.
dB(A) 94,95
Schalldruckpegel am Ohr des Bedieners. Siehe
Anmerkung 3.
dB(A) 84,06
54 668 - 002 - 13.06.2018