Chapter 6 Maintenance and Inspection 
 
99 
Error 
code 
Error 
type 
Alert indication  Alert contents  Actions to take 
403 to 
412 
CAUTION  Sensor reception 
failure (DAU2-CH*) 
*: 1 to 10 
The sensor data can't 
receive from the DAU. 
1) Check the wiring between the 
RCU and the DAU. 
2) Check the wiring between the 
DAU and the sensor. 
3) Check the equipment that is 
displayed. 
413  CAUTION  Sensor reception 
failure (DAU2-DAU) 
The DAU output data 
can't receive. 
1) Check the wiring between the 
RCU and the DAU. 
2) Check the DAU. 
414  CAUTION  Sensor reception 
failure (DAU2-ADC) 
The output data of 
DAU's built-in analog 
interface can't receive. 
1) Check the wiring between the 
RCU and the DAU. 
2) Check the DAU. 
415  CAUTION  Sensor reception 
failure (DAU2-GYRO) 
The output data of 
DAU's built-in gyro 
interface can't receive. 
1) Check the wiring between the 
RCU and the DAU. 
2) Check the DAU. 
416 to 
425 
CAUTION  Sensor reception 
failure (DAU3-CH*) 
*: 1 to 10 
The sensor data can't 
receive from the DAU. 
1) Check the wiring between the 
RCU and the DAU. 
2) Check the wiring between the 
DAU and the sensor. 
3) Check the equipment that is 
displayed. 
426  CAUTION  Sensor reception 
failure (DAU3-DAU) 
The DAU output data 
can't receive. 
1) Check the wiring between the 
RCU and the DAU. 
2) Check the DAU. 
427  CAUTION  Sensor reception 
failure (DAU3-ADC) 
The output data of 
DAU's built-in analog 
interface can't receive. 
1) Check the wiring between the 
RCU and the DAU. 
2) Check the DAU. 
428  CAUTION  Sensor reception 
failure (DAU3-GYRO) 
The output data of 
DAU's built-in gyro 
interface can't receive. 
1) Check the wiring between the 
RCU and the DAU. 
2) Check the DAU. 
429 to 
438 
CAUTION  Sensor reception 
failure (DAU4-CH*) 
*: 1 to 10 
The sensor data can't 
receive from the DAU. 
1) Check the wiring between the 
RCU and the DAU. 
2) Check the wiring between the 
DAU and the sensor. 
3) Check the equipment that is 
displayed. 
439  CAUTION  Sensor reception 
failure (DAU4-DAU) 
The DAU output data 
can't receive. 
1) Check the wiring between the 
RCU and the DAU. 
2) Check the DAU. 
440  CAUTION  Sensor reception 
failure (DAU4-ADC) 
The output data of 
DAU's built-in analog 
interface can't receive. 
1) Check the wiring between the 
RCU and the DAU. 
2) Check the DAU.