8─38 
8.5  Adjustments
yyyy
yyyy
8
Equipment Setup 
1. Bearing Adjustment
0.0° 
2. Range Adjustment
0
0
8. INSTALLATION      > 
0. EXIT 
3. Tune Adjustment
4. TRX Setting          >
5. COM Port Setting    >
6. NAV Setting         >
7. Sector Blank         >
 
9. Language 
ENGLISH
Range Adjustment 
 
 
Adjust the range so that the range of the target on the radar video is indicated correctly. 
 
 
 Procedures   1  Search the radar display for a target 
of which range is already known. 
 
2  Open the Equipment Setup Menu. 
 
3  Press [2] key. 
 
The Code Input Menu will appear. 
 
4  Using numeric pad, enter the value 
and then press “ENT” button, and 
press “EXIT” button to determine 
the value. 
 
The multi-function control can also be used 
to enter the value. 
 
5  Repeat step 4, and adjust until the 
target range measured in step 1 and 
the range on the radar display 
become identical. 
 
 
 
 Exit   1  Press [RADAR MENU] key. 
 
The Main Menu will reappear.