To return the EBL starting point to own ship's position 
 
 
 Procedures   1  Make EBL1 or EBL2 operable. 
 
  2  Press the [EBL] dial to set          for the EBL1 / EBL2 starting point 
mode switching (upper right of the display  ⑪/⑫ on page 2-19). 
 
The selected EBL starting point will be set as the own ship's position. 
 
 
 
[III]    Setting EBL Operation Mode 
 
 
To set the numeric value display mode of EBL (EBL Bearing REF) 
 
Determine whether to display EBL in true bearing mode or relative bearing mode. 
 
 
 Procedures   1  Put the cursor on the EBL1/2 numeric value indication true / relative 
switching (upper right of the display  ⑨/⑩ on page 2-19), and press 
the [ENT] key. 
 
The selected mode is switched as shown below each time the [ENT] key is pressed. 
 T  ⇒ R  ⇒  T  
 
    T    :EBL bearing is displayed in true bearing mode. 
    R    :EBL bearing is displayed in relative bearing mode. 
 
 
To set a mode for fixing EBL display (EBL Bearing Fix) 
 
When this function is set to    Angle , an EBL is fixed to the preset bearing.    For example, 
if a true bearing of 020° is preset, the EBL is fixed to the true bearing 020° even when the 
own ship turns. 
When the function is set to    Screen , the EBL is fixed on the radar display.    In this case, 
the EBL is always fixed to the same bearing on the display when the own ship turns. 
 
 
 Procedures   1  Press the [RADAR MENU] key twice. 
 
  2  Open the EBL/Cursor Setting menu by performing the following menu 
operation. 
 
   5. Sub Menu   
   9. EBL/Cursor Setting   
 
  3  Press [1] or [2] key. 
 
To set EBL1, press the [1] key, to set EBL2, press the [2] key 
 
    Angle    :EBL bearing is fixed to the preset value. 
    Screen    :EBL bearing is fixed on the radar display. 
 
Note:  Course data is necessary for turning on this function. 
4-5