5ļ¼38
JMA-9100 Instruction Manual > 5.OPERATION OF TARGET TRACKING AND AIS > 5.4 DECISION OF TARGETS AS IDENTICAL
(Association)
5.4 DECISION OF TARGETS AS
IDENTICAL (Association)
5.4.1 Setting of Function to Decide Targets as Identical
(Association)
When an AIS target and a tracking target are decided to be identical, an
association symbol is displayed for the targets regarded as identical. In this case,
the AIS target symbol is automatically activated.
怀怀怀怀怀怀怀怀
Procedures
1) Left-click the in Target Information located at the upper
right of the display.
Association will be set to on or off.
5.4.2 Setting of Conditions for Deciding AIS and Tracked Targets
as Identical (Association Setting)
Procedures
1) Open the Association Setting menu by performing the following
menu operation.
→
The Association Setting menu will appear.
2) Select and enter the item to be set.
Conditions for deciding targets as identical will be set. When the differences of all item
between AIS and tracked target are under the set conditions..
• Turn off in order not to make a decision
on if targets are identical, or in order to display
symbols that have disappeared.
Attentio n
Association
Association
AIS
1. Association Setting

Table of Contents

Other manuals for JRC JMA-9122-9XA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JRC JMA-9122-9XA and is the answer not in the manual?

JRC JMA-9122-9XA Specifications

General IconGeneral
BrandJRC
ModelJMA-9122-9XA
CategoryMarine Radar
LanguageEnglish

Related product manuals