ix
Microwave radiation level:
Keep away from a scanner when it is transmitting. 
The high level of microwave is radiated from the front 
face of the scanner specified below.  The microwave 
exposure at close range could result in injuries 
(especially of the eyes).
 Microwave radiation level 
System 50 W/m
2
  10 W/m
2
  2.5 W/m
2
NKE-2103 n/a 26cm 123cm
NKE-1125/1129/2254 5cm 81cm 162cm
NKE-1130/1139 11cm 76cm 181cm
!
Make sure to install the scanner at a place higher than 
human height.
Direct exposure to electromagnetic waves at close range 
will have adverse effects on the human body.
!
Direct exposure to electromagnetic waves at close range 
will have adverse effects on the human body. When it is 
necessary to get close to the scanner for maintenance or 
inspection purposes, make sure to turn the indicator 
power switch to "OFF" or "STBY."
Direct exposure to electromagnetic waves at close range 
will have adverse effects on the human body.
!
When conducting maintenance work, make sure to turn 
off the power so that the power supply to the equipment 
is completely cut off.
Some equipment components can carry electrical current 
even after the power switch is turned off, and conducting 
maintenance work without unplugging the power 
connector may result in electrocution, equipment failure, 
or accidents.