Chapter 2 System Configuration 2-64
If some number of CMH-2370s have been installed and connected to the same SENSOR LAN
UNIT NQE-2443, you should change IP address of each CMH-2370 by S3 setting. Refer to
Table.
2.5.15.
CMH-2370 to be connected to the IAS (Integrated Automation System) or AMS (Alert
Management System) is set the operation mode: ALC (Alert LAN Converter). Also in this case, set
the IP address in refer to
Table. 2.5.15.
Fig. 2.5.4 Outline of S3
The location of S3, refer to Fig. 2.5.5.
Table. 2.5.15 IP Address setting table
SFI:System Function ID of each IEC 61162 channel will also be changed depending on the IP
address.
S3
Position
Mode No.
IEC61162-450 JRC Format
Main LAN Sub LAN Main LAN Sub LAN
0
SLC
SLC1
172.16.60.107 172.17.60.107 192.168.60.107 192.168.61.107
1
SLC2
172.16.60.108 172.17.60.108 192.168.60.108 192.168.61.108
2
SLC3
172.16.60.109 172.17.60.109 192.168.60.109 192.168.61.109
3
SLC4
172.16.60.110 172.17.60.110 192.168.60.110 192.168.61.110
4
SLC5
172.16.60.111 172.17.60.111 192.168.60.111 192.168.61.111
5
SLC6
172.16.60.112 172.17.60.112 192.168.60.112 192.168.61.112
6
SLC7
172.16.60.113 172.17.60.113 192.168.60.113 192.168.61.113
7
SLC8
172.16.60.114 172.17.60.114 192.168.60.114 192.168.61.114
8
SLC9
172.16.60.115 172.17.60.115 192.168.60.115 192.168.61.115
9
SLC10
172.16.60.116 172.17.60.116 192.168.60.116 192.168.61.116
A
SLC11
172.16.60.117 172.17.60.117 192.168.60.117 192.168.61.117
B
SLC12
172.16.60.118 172.17.60.118 192.168.60.118 192.168.61.118
C
ALC
ALC1
172.16.60.119 172.17.60.119 192.168.60.119 192.168.61.119
D
ALC2
172.16.60.120 172.17.60.120 192.168.60.120 192.168.61.120
E
ALC3
172.16.60.121 172.17.60.121 192.168.60.121 192.168.61.121
F
ALC4