Attention:
Carefully read through the instal-
lation and operating instructions
and safety information before
installing and putting the unit into
service.
These must always be issued to
the owner/user.
Installation and
operating instructions
JUDO PROFIMAT-PLUS ¾" - 2"
JUDO PROFIMAT DN 65 - 100
Automatic backwash protective filter
Valid for: EU countries and Switzerland
Language: English
Fig.: JPF-A DN 65 - 100
Fig.: JPF
+
-A ¾" - 1¼"
Fig.: JPF
+
-A 1½" - 2"
Question and Answer IconNeed help?

Do you have a question about the Judo PROFIMAT-PLUS JPF+-ATP 1" and is the answer not in the manual?

Judo PROFIMAT-PLUS JPF+-ATP 1" Specifications

General IconGeneral
Operating pressure max.10 bar
Ambient temperature max.40 °C
Connection nominal size1"
Mesh size100 µm
Mains voltage230 V AC
Filter MediaStainless steel
Filtration Rating100 µm
Connection TypeThreaded

Summary

About this instruction manual

Safety information and dangers due to non-compliance

Details critical safety warnings and the risks associated with non-compliance with instructions.

Intended use

Notes on special dangers

Highlights specific hazards related to electrical installations and potential-free inputs/outputs.

Installation

General

Provides overarching guidelines for filter installation, including required personnel and pipe support.

Requirements for the place of installation

Specifies environmental conditions and site requirements for safe and effective filter installation.

Discharging backwash water

Outlines requirements for wastewater connections and safe disposal of backwash water.

Operation

Commissioning

Provides step-by-step instructions for initial start-up, including filling and venting the filter.

Differential pressure control

Details how the differential pressure switch automatically triggers backwashing based on pressure changes.

Setting the backwashing interval

Guides the configuration of automatic backwashing frequency using DIP switches based on mesh size.

Backwashing

Describes the automatic backwashing process, its importance, and how it ensures continuous operation.

Modifications / changes / spare parts

Warns against unauthorized modifications and stresses the use of genuine JUDO spare parts.

Servicing / Repair

Outlines crucial safety precautions, including depressurizing, before performing servicing or repairs.

Fault

Maintenance

Warranty and services

Data sheet

Technical data

Presents key technical specifications including flow rates, temperature limits, and power requirements.