EasyManua.ls Logo

Julabo CORIO CP-1000F User Manual

Julabo CORIO CP-1000F
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Heating immersion circulator, open bath heating circulator,
refrigerated circulator
Original operating manual
1.950.0900.en.V05 12/2022
w ww. . com
information@itm.com1.800.561.8187

Table of Contents

Other manuals for Julabo CORIO CP-1000F

Question and Answer IconNeed help?

Do you have a question about the Julabo CORIO CP-1000F and is the answer not in the manual?

Julabo CORIO CP-1000F Specifications

General IconGeneral
Temperature Range-20°C to +100°C
Cooling Capacity at +20°C1000 W
Pump Capacity Pressure0.5 bar
DisplayLED
Power Supply230 V / 50 Hz
Cooling Capacity1 kW
Heating Capacity1 kW
Heater Power2 kW
Pump TypePressure
RefrigerantR134a
InterfaceRS232
Cooling Capacity at 0°C700 W
Cooling Capacity at -20°C300 W

Summary

About this manual

Warnings

Explanation of warning symbols (DANGER, WARNING, CAUTION, NOTE) and their meanings.

Intended use

Safety

Safety instructions

Crucial safety guidelines for operating the device safely and preventing hazards.

Safety symbols

Details the safety symbols affixed to the device and their importance.

Safety function

Explains protective devices like high temperature cut-off and low liquid level protection.

Product description

Function description

Describes the general function and operational capabilities of the circulator.

Operating and functional elements

Identifies and describes the physical controls and connection ports on the unit.

Alarm messages

Explains how alarms and warnings are indicated and what actions to take.

Transport and installation

Install the device at the operating location

Steps for setting up the device at its final installation site, ensuring proper placement.

Initial operation

Mounting the circulator

Detailed steps for physically mounting the circulator onto a bath tank or cooling machine.

Connect the device to the power supply

Instructions for connecting the circulator to the electrical power supply.

Connecting an external system

Guidelines for connecting external, closed-loop systems to the circulator.

Set high temperature safety function

How to set the high temperature cut-off to prevent overheating and ensure safety.

Fill device

Instructions for filling the device with the appropriate bath fluid.

Operation

Switch on the unit

Procedure for powering on the device and initial startup sequence.

Switch off the unit

Instructions on how to properly shut down the device.

Configuring setpoint temperature

How to set and adjust the desired operating temperature setpoint.

Start temperature control application

Steps to initiate a temperature control application on the unit.

Adjusting the temperature sensor (ATC)

How to adjust the internal temperature sensor for improved accuracy.

Maintenance

Check the functionality of high temperature cut-off

Procedure to test the operational status of the high temperature safety function.

Test the low liquid level safety function

Steps to verify the correct operation of the low liquid level safety mechanism.

Disposal

Appendix

Alarms and Warnings

Details alarm and warning messages and their troubleshooting steps.