Do you have a question about the Julabo Presto Series and is the answer not in the manual?
Temperature Stability | ±0.01°C |
---|---|
Interfaces | RS232, USB |
Safety Features | Over-temperature protection, low liquid level alarm |
Display | TFT Touchscreen |
Power Supply | 230V, 50/60Hz |
Working Temperature Range | -20°C to +150°C |
Describes how to input and set the desired temperature value using the keypad.
Covers managing user access, passwords, and safety settings for the unit.
Configure parameters for internal or external temperature control, including self-tuning.
Fine-tune control parameters (Xp, Tn, Tv) for internal and external control to adapt to processes.
Define minimum and maximum values for settings like capacity, temperature, and pump limits.
Allows creation or editing of temperature profiles, defining setpoints and durations for each step.
Selects a profile and defines its start time, repeats, and end behavior.
Utilizes black box data for remote diagnosis, exportable for service assistance.
The service menu requires a password and is only accessible by authorized personnel.
Configure minimum/maximum setpoints, subtemperature, and overtemperature warning limits.
Configure pressure limits, including pump stages, setpoints, and warning levels.
Sets upper/lower warning limits for monitoring system pressure, with audible/visual alerts.
Sets minimum and maximum flow rate setpoints and warning limits for system monitoring.
Sets warning limits for flow rate, triggering alerts when limits are exceeded or undercut.
Enables or disables remote control via digital interfaces like RS232, USB, or Ethernet.
Manages settings for digital interfaces like RS232, Ethernet, and Watchdog function.
Connects the unit to a PC or network via Ethernet, configuring IP address and subnet mask.
Sets setpoint or controls heater variable via external voltage/current source connected to REG+E-PROG.
Procedure for filling the unit with heat transfer liquid, including safety and level checks.
Guides on safely draining the bath fluid, including precautions and procedure.
Procedure for calibrating internal and external temperature sensors for accurate readings.
Resets unit parameters to factory defaults, with a confirmation prompt.
Saves and loads unit settings to/from an external data carrier for backup or transfer.
Applies configuration files from a USB stick via the CAN Bus interface for unit setup.
Updates the unit's electronic modules using a USB stick containing the firmware update file.
Provides a comprehensive list of alarm codes, their causes, and diagnosis/remedy.
Details warning codes, their causes, and suggested diagnosis or remedies.
Details communication protocols, command sequences (in/out), and data transfer with PCs.
Starts CerHost and connects to the PRESTO unit using its IP address for remote display.