3 Operation
Switching the light on manually
Press the LB Management push-button 1-gang on the pulse insert or the
push-button. Light is switched on independently of the brightness for the run-
on time. LED (2) on automatic RMD lights up.
The run-on time is restarted if actuation is repeated.
In conjunction with motion detectors and push-buttons, long operation on the
button can lead to the motion detectors being restarted. During this time, the
motion detector cannot be operated via app.
Setting the automatic RMD
Image1: Automatic RMD
Automatic function without switch-off warning. The lighting is switched off
after the run-on time elapses.
Automatic function with switch-off warning. After the run-on time elapses,
the lighting is not switched off immediately, but rather only after flashing
three times at intervals of 10 seconds.
Light is switched on continuously.
ƒ Light is switched off continuously.
Power unit for rail mounting, Pulse insert