6 Troubleshooting
Light switches on but not off
Cause 1: The overload protection of the control input has tripped on the automatic
RMD, because too many pulse inserts or push-buttons are connected.
Reduce number of connected devices.
Cause 2: The overload protection of the control input has tripped on the automatic
RMD, because the automatic RMD has been installed too close to an external heat
source, e.g. a dimmer.
Check installation situation, ensure better cooling.
Light does not switch off.
Cause: Constant motion in detection field of motion detector cover.
Check installation situation of motion detector cover.
Reduce sensitivity on the motion detector cover (see instructions for the cover).
Replacing defective devices in systems with light management devices
Automatic RMD is defective.
The automatic RMD can be replaced one to one.
Light management pulse insert or cover is defective.
LB management covers and system inserts (1708IE) can only be used in
combination in existing installations. (Observe current consumption)
7 Accessories
LB Management push-button 1-gang Art. no. ..1700..
LB Management motion detector 1.1 m Art. no. ..17180..
LB Management motion detector 1.1 m Art. no. ..17182..
LB Management motion detector 2.2 m Art. no. ..17280..
8 Warranty
The warranty is provided in accordance with statutory requirements via the specialist
trade.