Rated voltage AC 230 V~
Mains frequency 50 Hz
Power consumption approx. 1 W
Ambient temperature +5 ... +45 °C
Run-on time approx. 10 s ... 15 min
Tolerance ± 20 %
Control input A1
Current carrying capacity 40 mA
Switching voltage AC 250 V~
Ohmic switching current 16A
Switch-on current 20 ms max. 165 A
Minimum switching current AC 100 mA
Connected load
Incandescent lamps 2300 W
HV halogen lamps 2300 W
HV-LED lamps typ. 400 W
Fluorescent lamps, uncompensated 1200 VA
Fluorescent lamps, parallel compensated 920 VA
Fluorescent lamps, duo circuit 2300 VA (140 μF)
Electronic transformers 1500 W
Inductive transformers 1000 VA
Electronic ballast Type-dependent
Installation width 18 mm / 1 HP
Total line length
Power cable max. 100 m
Control cable max. 100 m
Pulse insert, art. no. 1708IE
Rated voltage AC 230 V~
Mains frequency 50 Hz
Power consumption depending on the
cover
0.25 ... 0.45 W
Current consumption approx. 2.8 mA
Ambient temperature -5 ... +45 °C
Pulse duration approx. 60 ms
Pulse stop approx. 8 s
Power unit for rail mounting, Pulse insert
8 / 10
82599523 15.08.2022