No. 52024
V-21F
V-21FR3
V-21FMG3B
21
Item
Measuring
instrument
Test point Ad justment part Description
Ad just ment
of DELAY
POI NT
(AGC)
Signal
generator
Remote
control unit
DELAY POINT
(AGC TAKE-OVER)
1. Inp ut a blac k an d wh it e signal (colo ur of f) .
2. En ter th e SERVICE ME NU.
3. Select 1. IF f rom t he SERVI CE MENU.
4. Select 2 . DELAY P OINT by pressin g th e 2 key on the remote
control unit.
5. Set the set tin
valu es of th e set tin
item s as s ho wn bello w t able .
6. Then adjust the MENU - or + key until video noise disappears.
7. Turn to oth er ch an nels and make su re th at the re ar e n o
irregularities.
Setting Item Variable range Initial setting v alue
MATSUSHITA
A
2
7-
1
MURATA
A
1
-
4
ALPS
A
2
2-
1
NT SC 3.5 8
45 45 47
DELAY POINT
(AGC TAKE OVER)
OTHER
0~127
35 45 35
DELAY POINT UHF
AGC TAKE-OVER
**
- / + : OPERATE DISP : EXIT