23
Item
Measuring
instrument
Test point Adjustment part Description
[Method of adjustment using measuring instrument]
Adjustment
Of SECAM BL
(BLACK OFFSET)
z
Remote
control
unit
z
Signal
generator
7. SECAM BL ADJUST
1. Receive a SECAM HALF COLOUR BAR signal (210.25MHz).
2. Select
2. V/C
from SERVICE MENU.
3. Select
7. SECAM BL ADJUST
with
▼
/
▲
MENU key.
4. Set the initial setting value with the – or + MENU key.
5. Switch the
①
key (colour OFF) and
②
key (colour ON) on the
remote control and make sure that there is no colour on the
black and white screen.
6. If the black and white screen is not best with the initial setting
value, make fine adjustment until you get the best black and
white screen.
7. Press the DISPLAY key twice to return to the normal screen.
REMOTE CONTROL UNIT
12 3
4
56
7
8
9
COLOUR
ON
COLOUR
OFF