(No.MB161)1-43
5.4 Service mode
5.4.1 Confirming contents
(1) System micon reset
(2) System micon cold start
(3) FL display check
(4) Micon version check
5.4.2 Confirming methods
1. System micon reset
When CD mechanism stuck, this may solve the problem without removing/inserting power cord.
System micon is initialized.
Press the
STANDBY/ON, CANCEL
and buttons on the main unit
simultaneously.
2. System micon cold start
This function clears all user setting, and return to initial setting.
Daily timer, REC timer
Tuner preset
SEA preset
Last condition (Source, Volume)
This unit returns to initial setting.
While pressing both the CANCEL and
buttons on the main unit, insert the
power cord in an outlet
3. FL display check
This enables all FL segment light up.
Operating method using a remote controller
Press the VOLUME UP, STOP and STANDBY/ON buttons
twice on the remote controller at standby.
All of the FL displays light up.
Press the VOLUME DOWN, STOP and
STANDBY/ON buttons on the remote
controller at standby.