Manual
nEnglish translation of German original
KACO blueplanet 87.0 TL3
KACO blueplanet 92.0 TL3
KACO blueplanet 105 TL3
KACO blueplanet 110 TL3
KACO blueplanet 125 TL3
KACO blueplanet 137 TL3
KACO blueplanet 150 TL3
KACO blueplanet 155 TL3
KACO blueplanet 165 TL3
These instructions form part of the product and must be carefully read, observed and stored in a place which is freely accessible
at all times.
Authorised electrician
Important safety instructions

Table of Contents

Other manuals for Kaco blueplanet 92.0 TL3

Questions and Answers:

Kaco blueplanet 92.0 TL3 Specifications

General IconGeneral
Rated Power92000 W
Max. apparent AC power92000 VA
Maximum DC Input Voltage1100 V
AC voltage range320 V - 480 V
AC frequency50 Hz / 60 Hz
Nominal AC Voltage400 V
Power Factor0.8 leading - 0.8 lagging
THD< 3 %
MPPT Voltage Range450 V - 850 V
Nominal AC Output Power92 kW
Maximum AC Output Power92 kW
Operating Temperature Range-25°C to +60°C

Summary

Safety

Technical Data

Electrical Data

Provides detailed electrical specifications for various KACO blueplanet models.

Installation and Preparation

Selecting an Installation Location

Details safety considerations and requirements for choosing an installation site.

Installing and Securing the Device

Provides safety instructions for lifting and securing the device after the mount is installed.

Installation

Making the Electrical Connections

Provides instructions for making electrical connections, emphasizing compliance with standards.

Connecting the Device to the Mains Supply

Preparing the Grid Connection

Details the steps for preparing the AC connection, including cable routing and lug fitting.

Making the Grid Connection

Explains how to make the 4-pole grid connection for TN and TT systems.

Connecting the PV Generator to the Device

Checking the PV Generator for a Ground Fault

Guides on checking the PV generator for ground faults to prevent electric shock.

Connecting the PV Generator

Details safety warnings and steps for connecting the PV generator to the device.

Start-up

Start-up Options

Outlines various methods for starting up the device and its configuration.

Configuration and Operation

Initial Start-up

Provides notes on ensuring DC power supply during initial start-up.

User Interface

Details the monitoring interface of the device, including key areas and their functions.

Menu Structure

Explains the menu structure, including password protection for grid parameters.

Specifications

Reactive Power Control

Explains the role of reactive power in grid stability and inverter contribution.

Reactive Power Functions

Lists and explains the implemented reactive power control functions.

Regulating Active Power

Active Power Limitation

Details active power limitation functions like P set and P limit.

Voltage-Dependent Power Reduction P(U)

Details voltage-dependent power reduction using characteristic curves.

P(f) Active Power Response to Overfrequency

Explains how the device responds to grid overfrequency for stability.

Other Grid Support Functions Effective on Active Power

Permanent Power Gradient Limitation

Details permanent power gradient limitations for plant operation.

Advanced Islanding Detection

Enhanced Island Detection Method

Explains KACO's strategy for reliable island detection and prevention.

Maintenance and Troubleshooting

Shutting Down for Maintenance / Troubleshooting

Disconnecting the Connections

Provides steps for disconnecting AC and DC cables.

Faults

Procedure

Lists general safety warnings and procedures for handling faults.

Rectifying Faults

Details faults, causes, explanations, and remedies, categorizing actions.

Troubleshooting

Provides a table of status and fault messages displayed by the device.

Decommissioning and Removal

Service and Warranty

Related product manuals