Register Address
Address
Content
R/W Property
Comments
Input register 0
PM2.5
R
0-999 ug/m3
Input register 1
TVOC
R
0-9999 ppb
Input register 2
Temperature
R
-30.0-50.0
Input register 3
Humidity
R
0.0%-100% RH
Input register 4
CO2
R
0-9999 ppm
Input register 5
PM10
R
0-999 ug/m3
Input register 6
HCHO
R
0-2000 ppb
Input register 7
CO
R
0.0-500.0 ppm
Input register 8
O3
R
0.0-100.0 ppm
Input register 9
Reserved
R
Input register 10
Reserved
R
Input register 11
Reserved
R
Input register 12
Reserved
R
Input register 13
Reserved
R
Input register 14
AQI
R
0-500