Do you have a question about the Kärcher HDS 995 MX Eco and is the answer not in the manual?
Category | Floor Machine |
---|---|
Model | HDS 995 MX Eco |
Manufacturer | Kärcher |
Voltage (V) | 230 |
Motor Power | 6.5 kW |
Frequency | 60 Hz |
Diagram showing all components of the high-pressure cleaner unit with numbered references.
List and description of all buttons, switches, regulators, and indicators on the unit.
Explanation that item numbers in instructions correspond to the unit illustration.
Steps for initial setup including checking oil, filling scale inhibitor, fuel, and cleaning agent.
Instructions on using correct fuel types (diesel/light fuel oil) and warnings against unsuitable fuels.
Guidelines for using cleaning agents, including product type, safety, and handling instructions.
Connect steel pipe, handgun, and hose reel. Mount spare hose and handle. Ensure secure connections.
Connect water supply hose and mains power. Draw water from tank if needed. Check connections.
Set unit switch to 'I'. Check indicators and temperature regulator setting before starting.
Set cleaning temperature and adjust operating pressure/flow rate using controls and regulator.
Measure agents sparingly. Use appropriate nozzles. Clean with cold or hot water/steam.
Apply cleaning agent, let it react, then rinse with high-pressure jet.
Operate with hot water (30-90°C) or steam (100-150°C). Follow safety warnings.
Unit automatically switches off if handgun is inactive for >30 mins. Reset using main switch.
Turn unit off, shut off water, remove plug, depressurize, secure handgun.
Protect unit from frost by draining and storing in a frost-free location. Disconnect from flue below 0°C.
Drain water and flush with antifreeze for extended non-use or if frost-free storage is not possible.
Clean strainers and fine filter, check oil level.
Clean low water protection strainer and cleaning-agent suction hose filter.
Change the engine oil. Perform other tasks as indicated by warning lamps.
Interpret error codes shown on the display (e.g., 2, 3, 6, 7) for specific fault diagnosis.
Address issues indicated by 'Ready for working' lamp out, Fuel lamp on, or Scale inhibitor lamp on.
Check power supply and connections if unit does not run. Bleed pump to resolve pressure issues.
Address empty tanks, dirty filters, insufficient water supply, and cleaning agent draw issues.
Check for leaks in the pump or high-pressure system. Troubleshoot unit switching on/off or not drawing agent.
Troubleshoot burner ignition, temperature attainment, and soot deposits on the heating coil.
Explanation of overflow valve, safety valve, low water protection, and motor protection switch functions.
Notes on startup procedures, potential voltage drops, and mains impedance requirements.
Details measured and guaranteed sound power levels for HDS 995 and HDS 1295 models.
Company details, registration information, and contact data for Alfred Kärcher GmbH & Co. KG.