www.kaercher.com 5.961-300 A2008544 05/04
HDS 995 M Eco HDS 995 MX Eco
HDS 1295 S Eco HDS 1295 SX Eco
Question and Answer IconNeed help?

Do you have a question about the Kärcher HDS 1295 S Eco and is the answer not in the manual?

Kärcher HDS 1295 S Eco Specifications

General IconGeneral
CategoryFloor Machine
ModelHDS 1295 S Eco
ManufacturerKärcher
Dimensions (L x W x H)1330 x 750 x 1060 mm
Voltage400 V
Frequency50 Hz
Hose Length10 m
Flow rate600 - 1300 l/h
Operating pressure30 - 180 bar
Power rating2800 W
Working Pressure30 - 180 bar
Water Flow Rate600 - 1300 l/h
Power Consumption2800 W
Lance Length0.5 m

Summary

Operating Controls

Commissioning

Filling with Fuel

Fill the unit with diesel fuel or light fuel oil only. Never operate with an empty tank.

Drawing in Water from Tank

Mains Connection

Operation

Switch On The Machine

Set unit switch to "I". Ensure ready for working indicator lamp is lit.

Setting Cleaning Temperature

Adjust the temperature regulator to the required temperature for hot water or steam cleaning.

Setting Operating Pressure and Flow Rate

Adjust pressure and flow using the control spindle and pressure/flow control.

Working with High-Pressure Nozzle

Spray angle is crucial for efficiency. Use 25° fan jet nozzle normally.

Cleaning

Set pressure, temperature, and detergent concentration. Start from a distance.

Recommended Cleaning Method

Spray cleaning agent, let it react, then spray off loosened dirt.

Operation with Hot Water

Use appropriate temperatures for different cleaning tasks. Beware of scalding.

Operation with Steam

Replace nozzle, set pressure to minimum, and temperature to min. 100°C. Beware of steam.

After Every Operation

Stopping Machine

Turn off unit, shut off water, remove plug, depressurize, and secure handgun.

Maintenance

Engine/Electronics Indicator Lamp

Warning lamp indicates necessary maintenance work based on operating hours.

Change Oil

Provide container, unscrew plug, drain oil, retighten, and top up slowly.

Faults

Ready For Working Indicator Lamp Goes Out

Address motor overload or no mains voltage issues.

Unit Does Not Run

Check for no mains voltage or issues with the electric mains/power cord.

Unit Does Not Build Up Pressure

Check for air in the system and bleed the pump.

Burner Not Ignited

Check fuel tank, water supply, and fuel filter. Check rotation direction.

Technical Data