How to fix defective vehicle lighting on a Kärcher Floor Machine?
- SShannon HendersonSep 7, 2025
If there is defective vehicle lighting, check and replace fuses, connectors, and lamps.
How to fix defective vehicle lighting on a Kärcher Floor Machine?
If there is defective vehicle lighting, check and replace fuses, connectors, and lamps.
Why are the brushes on my Kärcher Floor Machine failing to rotate or rotating too slowly?
If the brushes fail to rotate or rotate too slowly, check the pressure in the working hydraulic circuit and adjust the pressure relief valve.
What to do if the starter turns the engine but the Kärcher ICC 1 S D doesn't start?
If the starter turns the engine but it fails to start, you should check the battery voltage. Also, verify the fuel level and top it up if needed. Furthermore, check and replace the fuel filter and air cleaner element. You may also need to check or replace fuses F12 and F1, the glow plug control module D1, the engine shutoff solenoid valve Y1, and the starter drive gear.
How to troubleshoot a Kärcher Floor Machine when the starter fails to turn the engine?
If the starter fails to turn the engine, you should check and replace fuse F1. Also, check the ground connection between the engine and chassis, and inspect the battery G1 for voltage, electrolyte level and density. Furthermore, check and replace the ignition switch S1. You may also need to check the voltage at the starter relay and terminals, and check or replace the starter.
What to do if the Kärcher ICC 1 S D Floor Machine engine cannot be shut off?
If the engine cannot be shut off, you should check the engine shutoff control module D2. Additionally, check or replace the ignition switch S1 and the engine shutoff solenoid valve Y1.
Why is my Kärcher Floor Machine engine emitting black smoke?
If the engine emits black smoke, you should check and replace the air cleaner element. Also, check the fuel return lines.
Why aren't the stop lights working on my Kärcher ICC 1 S D?
If the stop light is without function, check or replace fuse F15 and stop light switch S19.
Why is the windshield wiper not working on my Kärcher ICC 1 S D?
If the windshield wiper is without function, check and replace fuse F7, relay K6, and wiper motor M4.
Why is the blower not working on my Kärcher ICC 1 S D?
If the blower is without function, check or replace switches S10 / S11 on the debris container. Also, check or replace relay K1, fuse F4, check or adjust the V-belt and check the magnetic clutch.
Why is my Kärcher Floor Machine not developing sufficient suction?
If the machine fails to develop sufficient suction, check and clean the chain curtain in the debris container. Also, check the vacuum intake and impeller fan. Furthermore, check, adjust, or replace the sealing lips on the vacuum intake, check the vacuum intake condition and remove any blockage, check or replace the seal in the vacuum channel, and check, adjust, or replace the seals on the debris container.
Brand | Kärcher |
---|---|
Model | ICC 1 S D |
Category | Floor Machine |
Language | English |
Provides an overview of the machine's technical capabilities and design features.
Illustrates and lists the various controls and switches on the operator's console.
Details the indicators and displays on the instrument panel for monitoring machine status.
Explains the operation and components of the machine's sweeping and vacuum collection system.
Describes the water system used for dust suppression and cleaning.
Explains how to adjust and check the machine's sweeping pattern for optimal performance.
Details how to adjust the vacuum intake for proper ground clearance.
Explains how to adjust the drum brakes and notes their operation.
Provides instructions for changing wheels and removing the steering wheel.
Provides important guidelines and procedures for towing and transporting the machine safely.
Covers checking the hydraulic fluid level and topping up the system.
Details the procedure for replacing the hydraulic fluid filter.
Details how to check the hydraulic pressure for the drive system.
Explains how to adjust the pressure relief valve for various hydraulic functions.
Provides instructions for removing and installing the hydraulic pumps.
Details the procedure for removing and installing the impeller fan.