English 25
Often, failures have simple causes and you
can do the troubleshooting yourself using
the following overview. If you are in doubt or
if the failure is not listed here please contact
the authorized customer service.
Risk of electric shock!
Repair works may only be performed by the
authorized customer service.
Î Descale the steam boiler.
No water in the steam boiler. Water scarcity
thermostat switches off the heating.
Î Turn off the appliance.
Î See "Refilling Water" page 19
Steam switch ist secure with the lock / child-
proof lock (C3).
Î Push the steam switch lock (C3) to the
back.
The steam plug is not completely inserted
into the unit plug socket.
Î Tightly insert the steam plug (C6) into the
appliance connector (A1). The locks of
the steam plug must lock into the cover
of the appliance connector (see Fig. 1).
The terms of the guarantee applicable in
each country have been published by our re-
spective national distributors. We will repair
possible faults on your unit free of charge
within the warranty period, insofar as the
faults are caused by material defects or de-
fective workmanship. Guarantee claims
should be addressed to your dealer or the
nearest authorized customer service centre,
and supported by documentary evidence of
purchase.
No liability will be accepted if the appliance
is incorrectly operated or if the instructions
for use are not complied with.
Only use original Kärcher spare parts. You
will find a list of spare parts at the end of this
document.
Troubleshooting
Long heating-up time
Steam boiler is decalcified.
No steam
Red low-water indicator lamp lights up.
Steam lever cannot be pressed anymore
Check the steam plug
General notes
Warranty
Spare Parts
Specifications
Power connection
Voltage 220-240 V
Current type 1~ 50/60 Hz
Performance data
Heating output 1400 W
Operating pressure max. 3,0 bar
Heating time
per litre of water
7min
Max. steam quantity 50 g/min
Dimensions
Boiler capacity 1,2 l
Weight (without
accessories)
3kg
Width 195 mm
Length 385 mm