EasyManua.ls Logo

Karizma Plus - Quick-Set and Point Omission; Performing a Quick-Set; Omitting Points During Setting

Default Icon
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Performing a Quick-Set
It is possible to override the programmed exit time by use of the Quick Set function. This always gives you 3
seconds to vacate the protected area. Quick Set is selected during the first 5 seconds of the exit period
(while the red FUNCTION indicator is on) by pressing the QSET key on the keypad. To use this function with
one of the part-set programmes you must first select the part-set (SET B or SET C), and then press QSET.
Program QSet
PROGRAM A
Omitting points during setting
It is possible to omit one or more detection points when you set the system. The omitted points will not be
able to cause an alarm when the system has set. This facility may be useful if one of your detection points
has become faulty and keeps producing false alarms.
Because omitting a detection point degrades the security provided by your alarm system, your engineer may
have programmed only a limited number of points to be omittable. Check your SIS to see which points, if
any, can be omitted.
Points can be omitted by pressing the OMIT key during the first 5 seconds of the exit period (while the red
FUNCTION indicator is on).
01:FRONT DOOR
Omit Point: NO
The exit sound will stop, and the keypad will display the first point from a list of points that can be omitted.
Use the and keys (over the 8 and 9 keys) to step through the list of points until the point you want
to omit is displayed. Now press the ENTER key. The symbol will move onto the second line of the display.
Press the key to change the NO to YES, and press the ENTER key.
01:KITCHEN PIR
Omit Point:YES
The point will be omitted and the exit period will start again.
You can omit as many points as you want using this procedure. To omit points from a part-set program you
must first select the part-set by pressing SET-B or SET-C.