Power supply
Possible cause
Battery voltage too low
Connector contacts and connections
faulty
12 V switch on refrigerator off
Fuse on control panel triggered
Refrigerator or cabling faulty
Fuse on starter battery or control
panel faulty
Relay in charging device faulty
Bad electrical contacts (too loose)
Fuse triggered
Remedy
Charge body battery, start motor and
allow to run for approx. 30 seconds.
Battery voltage rises over 12 V and
charging starts.
Check and eliminate fault if
necessary
Take switch A into 12 V position
(Page 5-8)
Press in fuse (Page 6-1)
Contact specialist workshop
Change fuse
(Page 6-1, 6-3)
Contact specialist workshop or
change charger
Check and correct fault if necessary
Switch on circuit breaker
(Page 6-2)
Defect
Body battery does not charge when
connected to 230 V network
12 V operation of refrigerator not
possible during travel
230 V operation of refrigerator not
possible
D
FAULT IDENTIFICATION AND CORRECTION