D FAULT IDENTIFICATION AND CORRECTIOND
Water supply
11-6
Possible cause
Fresh water tank empty
Water pump fuse on control panel
triggered
Water pump faulty
Pipeline system leaks
Connection of control panel and
measuring probe interrupted
Measuring probe defective
Control panel defective
Measuring probe dirty because of
residues in water
Remedy
Fill fresh water tank
Push in fuse (Page 6-1)
Contact specialist workshop
Find fault and seal
Localise fault and close connection
Replace measuring probe
Contact specialist workshop
Clean measuring probe
Defect
No fresh water
Water in interior
Fresh water / discharge display on
control panel does not function