DE-ICER MANUAL
3
UNIT SPECIFICATIONS AND SIZING CHART
Model Voltage Operating Amps Locked Rotor Amps Thrust (lbs.)
2400D
110-120 5.7 12 31
3400D 110-120 6.7 18 37
3400HD 208-240 3.1 9 37
4400D 110-120 9.1 40 42
4400HD 208-240 4.5 20 42
Average Low
Air Temperature
Orientation
Model
2400 3400 4400
34 °F to 20 °F
(-1 °C to 6.5 °C)
Angled 30’ x 100‘ 35’ x 120’ 40’ x 150’
Vertical 65’ 85’ 90’
19° F to 0° F
(-7° C to -18° C)
Angled 25’ x 60’ 30’ x 80’ 35’ x 90’
Vertical 50’ 70’ 80’
-1 °F to -20 °F
(-19 °C to -29 °C)
Angled 25’ x 55’ 30’ x 75’ 35’ x 85’
Vertical 35’ 50’ 65’
Great Lakes Angled 20’ x 40’ 25’ x 50’ 30’ x 60’
Vertical 30’ 45’ 55’
Sizing recommendations based on the following assumptions:
Unobstructed water.
200-acre+ body of water with 200 feet+ water depth.
Water depth in de-icing area is greater than 4 feet.
(Size may vary greatly based on a number of local conditions).