EasyManua.ls Logo

Katool KT-X80 - Page 26

Katool KT-X80
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
……………………………………………………………...
………………………………………………………………………….
24
8.2 Periodic Maintenance
Every 3
months
Hydraulic circuit
check oil tank level; re
fi
ll with oil, if needed;
check the circuit for oil leakage.
check seals for proper conditions and replace
them, if necessary;
Foundation bolts
check bolts for proper tightening
Hydraulic pump
verify that no noise changes take place in the
pump when running and check
fi
xing bolts for
proper tightening
Safety system
check safety devices for proper operation
Every 6
months
Oil
check oil for contamination or ageing.
Contaminated oil is the main reason for
failure of valves and shorter life of gears
pumps
Every
12
months
General check
verify that all components and mechanisms are
not damaged
Electrical system
a check of the electrical system to verify that
motor, limit switch and control panel operate
properly must be carried out by skilled
electricians
Oil
empty the oil tank and change the hydraulic oil