EasyManua.ls Logo

Kaysun KAM2-42 DR8 - User Manual

Kaysun KAM2-42 DR8
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
IMPORTANT NOTE:
Read this manual carefully before installing or operating your new air conditioning
unit. Make sure to save this manual for future reference.
This manual only describes the outdoor unit of user's. When using the indoor unit,
refer to the user's manual of indoor unit.
OWNER'S MANUAL
Outdoor Units R-32
KAM2-42 DR7
KAM2-52 DR7.1
KAM3-62 DR7
KAM3-78 DR7.1
KAM4-80 DR7
KAM4-105 DR7
KAM5-120 DR7
KAM5-120 DR8

Questions and Answers

Overview

This document is an owner's manual for Kaysun R-32 Outdoor Units, providing information on operation, maintenance, and troubleshooting for various multi-split air conditioning systems.

Function Description

The manual describes the outdoor units of multi-split air conditioning systems, which can be paired with different types of indoor units (Wall-Mounted, Duct/Ceiling, Floor and Standing (Console), and Compact Four-Way Cassette). The system is designed for cooling, heating, and dry modes, offering flexible climate control. It includes features like compressor protection, anti-cold air function (for heating models), defrosting (for cooling and heating models), auto-restart (on some models), and various operational indicators. The outdoor unit is responsible for drawing in heat (during heating mode) or releasing heat (during cooling mode) to facilitate temperature regulation within the indoor environment.

Important Technical Specifications

The manual outlines the operating conditions for safe and effective operation across different modes:

  • COOL Mode:
    • Room Temperature: 17°C - 32°C (63°F - 90°F)
    • Outdoor Temperature: 0°C - 50°C (32°F - 122°F)
    • Outdoor Temperature (for low-temp cooling systems): -15°C - 50°C (5°F - 122°F)
    • Outdoor Temperature (for special tropical models): 0°C - 52°C (32°F - 126°F)
  • HEAT Mode:
    • Room Temperature: 0°C - 30°C (32°F - 86°F)
    • Outdoor Temperature: -15°C - 30°C (5°F - 86°F)
  • DRY Mode:
    • Room Temperature: 17°C - 32°C (50°F - 90°F)
    • Outdoor Temperature (for special tropical models): 0°C - 52°C (32°F - 126°F)

The unit uses R-32 refrigerant, which is flammable, and servicing must be performed by skilled personnel competent in handling such refrigerants. The appliance should be stored in a well-ventilated area corresponding to the room size specified for operation.

Usage Features

  • Operation Mode Selection: When multiple indoor units are operating simultaneously, heat modes take precedence. If one unit starts in HEAT mode, others can only operate in HEAT mode. If a unit starts in COOL or FAN mode, others can operate in any mode except HEAT. Conflicting modes will cause other units to stop or display an error.
  • Compressor Protection: The compressor has a 3-minute protection feature, preventing immediate restart after being turned off to prevent overloading.
  • Anti-cold Air (Cooling and Heating Models Only): In HEAT mode, the unit is designed not to blow cold air when heating has just started, during defrosting, or during low-temperature heating, until the set temperature is reached.
  • Defrosting (Cooling and Heating Models Only): The unit automatically stops heating and initiates defrosting when frost builds up on the outdoor unit due to low outdoor temperature and high humidity. This process typically takes 4 to 10 minutes.
  • Auto-Restart (Some Models): In case of power failure, the system will stop and then restart with the same settings once power is restored, if this function is enabled.
  • Optimal Operation: Users are advised to adjust airflow direction, set comfortable temperatures, keep doors and windows closed in COOL or HEAT mode, use the TIMER ON button, avoid blocking air inlets/outlets, and clean air filters periodically.
  • Energy Saving Tips: Recommendations include avoiding excessive temperature settings, closing curtains during cooling, keeping doors and windows closed, ensuring air inlets/outlets are clear, using SLEEP/ECONOMY mode, removing remote control batteries during long periods of non-use, cleaning air filters every two weeks, and adjusting louvers to avoid direct airflow.

Maintenance Features

  • Long-Term Idleness: If the unit will be idle for a long time, users should clean the indoor unit and air filter, run the indoor fan in FAN ONLY mode to dry the unit's interior, disconnect power, and remove remote control batteries.
  • Periodic Outdoor Unit Checks: Components of the outdoor unit should be checked periodically, and a local dealer should be contacted if required.
  • Before Cleaning: Always switch off the unit and disconnect the power supply plug before cleaning.
  • Re-use After Idleness: Before using the air conditioner again, wipe dust from the rear air intake grille, check wiring, ensure the air filter is installed, and verify that air outlets/inlets are not blocked.
  • Troubleshooting: The manual provides a troubleshooting guide for common issues such as the unit not turning on, changes from COOL to FAN mode, white mist emission, noises, dust emission, bad odors, and the outdoor fan not operating. It also offers solutions for poor cooling and heating performance, including checking for power failures, dirty filters, refrigerant leaks, and system blockages.
  • Professional Servicing: For issues like continuous rapid flashing of the operation light, non-responsive remote control buttons, frequent tripping of fuses/circuit breakers, foreign objects/water entering the unit, or other abnormal situations, users are advised to switch off the power immediately and contact their dealer. Servicing involving flammable refrigerants (R-32) must be performed by certified and skilled personnel.

European Disposal Guidelines

Users in European countries are required to dispose of the unit properly due to the presence of refrigerant and potentially hazardous materials. Disposal options include designated municipal electronic waste collection facilities, returning the old appliance to the retailer when buying a new one, the manufacturer taking back the old appliance, or selling it to certified scrap metal dealers. It is explicitly stated not to dispose of the product as household waste or unsorted municipal waste, and not to dispose of it in natural surroundings to prevent environmental contamination.

Kaysun KAM2-42 DR8 Specifications

General IconGeneral
BrandKaysun
ModelKAM2-42 DR8
CategoryAir Conditioner
LanguageEnglish