WARNING
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner.
CAUTION
CLEANING & MAINTENANCE
OPERATION
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off
power unit.
4. Please read specification label on product for further information and requirements.
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit
with the dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noi-
ses, replace the motor with the exact service motor. The impeller should also be replaced.
See “Connect Wiring” for details.
The fan, light, and night light can be operated separately. Use a 3-function wall control. (For model SEP120L2)
MODEL: SEP120
SEP120L2
VENTILATION FAN
a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to
prevent power from being switching on accidentally. When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.
c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and standards.
d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such
as those published by the National Fire Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
f). Ducted fans must always be vented to the outdoors.
g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected
branch circuit (ceiling installation only).
h). This unit must be grounded.
i). Not for Use in Kitchens.
j). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces
within walls or ceilings or into attics, crawl spaces, or garages
k). WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed
Control Device.
l). The fan must not be installed in a ceiling thermally insulated to a value greater R40.
Cod: 0060301933
Question and Answer IconNeed help?

Do you have a question about the KAZE APPLIANCES SEP120 and is the answer not in the manual?

Summary

WARNING

General Safety Precautions

Follow manufacturer's instructions, disconnect power, use qualified personnel, ensure proper ventilation, and avoid electrical hazards.

CAUTION

Operating Cautions

Use for general ventilation only, avoid hazardous materials, ensure proper installation angle, and protect unit from dust.

CLEANING & MAINTENANCE

Maintenance Procedures

Clean grille and interior with dusting brush. Motor is permanently lubricated; replace if noisy.

OPERATION

Operating Modes

Fan, light, and night light can be operated separately using a 3-function wall control.

PLAN THE INSTALLATION

Installation Location and Ducting

Avoid cooking areas. Connect ductwork properly to the unit for optimal performance and ventilation.

ASSEMBLY INSTRUCTIONS

Hanger Bar and Framing

Install and adjust sliding hanger bars to fit framing, securing them accurately for ventilator positioning.

Ductwork Installation

Connect round ductwork to the unit, ensuring airtight connections and routing for optimal airflow and energy efficiency.

CONNECT ELECTRICAL WIRING

Wiring Diagrams and Connections

Provides wiring diagrams for SEP120 and SEP120L2 models, detailing connections for fan, light, and night light circuits.

INSTALL GRILLE

Grille Attachment

Secure the grille assembly to the fan housing by inserting the light plug and engaging the grille springs.

SERVICE PARTS

Parts Identification

Lists all replaceable parts with quantities and includes a diagram identifying each component of the ventilation fan.

WARRANTY

Warranty Coverage and Exclusions

Details the 12-month warranty for mechanical and electrical parts, and lists exclusions like improper installation and consequential damages.

Overview

This document describes the Kazé SEP120 and SEP120L2 Ventilation Fans, designed for general ventilating use in ceilings. These models are not intended for use in kitchens or for exhausting hazardous or explosive materials and vapors.

Function Description

The Kazé SEP120 and SEP120L2 are ventilation fans designed to exhaust air to the outdoors, preventing backdrafting and ensuring proper air circulation. The SEP120L2 model includes additional lighting features, offering a fan, light, and night light that can be operated separately using a 3-function wall control. These units are suitable for use over a tub or shower when connected to a GFCI-protected branch circuit (ceiling installation only).

Important Technical Specifications

  • Voltage: 120 V AC.
  • Installation: Designed for ceiling installation only, up to a 12/12 pitch (45-degree angle). The duct connector must point upwards. Not suitable for wall mounting.
  • Ducting: Requires round ductwork vented to the outdoors. Short, straight duct runs are recommended for optimal performance, and smaller ducts than recommended should be avoided. Duct joints should be sealed with tape to ensure airtight connections. Insulation around ducts can help reduce energy loss and inhibit mold growth.
  • Electrical Wiring: Installation and wiring must be performed by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes. The unit must be grounded.
  • Thermal Insulation: The fan must not be installed in a ceiling thermally insulated to a value greater than R40.
  • Speed Control: Not compatible with solid-state speed control devices.
  • Lighting (SEP120L2 only): Includes a light and a night light, operable separately from the fan.

Usage Features

  • General Ventilation: Primarily for general ventilating purposes, ensuring sufficient air exchange in the designated area.
  • Bathroom/Shower Use: Acceptable for use in bathrooms and over tubs or showers, provided it is connected to a GFCI-protected branch circuit.
  • Separate Operation (SEP120L2): The fan, light, and night light functions can be controlled independently with a 3-function wall control, offering versatility in use.
  • Quiet Operation: Designed for quiet and efficient operation. Users are advised to keep drywall spray and construction dust away from the power unit to prevent motor bearing damage and noisy or unbalanced impellers.
  • Installation Flexibility: Sliding hanger bars are provided, allowing the housing to be positioned accurately between framing members up to 24 inches apart. These bars are compatible with I-joist, standard joist, and truss construction.

Maintenance Features

  • Cleaning: For quiet and efficient operation, long life, and attractive appearance, the grille should be lowered or removed, and the interior of the unit vacuumed using a dusting brush attachment.
  • Motor Lubrication: The motor is permanently lubricated and does not require oiling.
  • Part Replacement: If the motor bearings produce excessive or unusual noises, the motor and impeller should be replaced with exact service parts. A service parts list is provided, including components like the grille assembly, grille spring, wire panel, lens, blower, blower wheel, motor plate, motor, hanger bar kit, housing, wiring plate, and damper/duct connector, along with various screws and washers.
  • Safety Precaution for Maintenance: Before servicing or cleaning the unit, the power must be switched off at the service panel, and the disconnecting means locked to prevent accidental power-on. If locking is not possible, a prominent warning device (e.g., a tag) should be securely fastened to the service panel.

Warranty Information

The product comes with a 12-month warranty covering defects in workmanship or materials for mechanical and electrical parts from the date of purchase. The original sales receipt is required as proof of purchase. The manufacturer will repair or replace defective parts under normal household use.

The warranty does NOT cover:

  • Damages from improper installation, shipping, misuse, abuse, accident, alteration, or lack of proper care and maintenance.
  • Damages from service by unauthorized personnel.
  • Labor, service, transportation, and shipping charges for part removal and installation beyond the initial 12-month period.
  • Fluorescent lamp starters and tubes.

This limited warranty is exclusive and replaces all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. The remedy provided is exclusive, and the warranty does not cover incidental or consequential damages. Specific legal rights may vary by state.