17
TROUBLESHOOTING
Problem Possible Cause Solution
The mixing bowl does
not rotate under load
Mixing bowl is overloaded
Turnopowertoolandcompletelyemptymixingbowl.Turnpowertoolonand
check.
V-Belt is slipping
Turnopowertool.ReferHOWTODOACHECKOFTHEV-BELT.
If belt is damaged replace part.
Pinion gear not turning
Check connection between pinion shaft and upper pulley. Check connection between
pinion gear head and shaft.
Gears are not engaged
Turnopowertool.Performvisualinspectionofpiniongearandcorrectalignment.
If gear is damaged replace part.
Mixing bowl will not tip
Bearing arm housing is
over-tightened
Turnopowertool.Loosenboltsandre-check.
No lubrication Turnopowertool.Checkandapplygreaseviagreasenipple.
Bearing arm has
interference
Turnopowertool.Performvisualinspectionforforeignobjects.
Unusual / excessive
noise
Fasteners are loose Check and tighten all bolts and nuts.
Pulleys not aligned correctly
Turnopowertool.ReferHOWTODOACHECKOFTHEV-BELT.Ifbeltisdamaged
replace part.
No lubrication
Turnopowertool.
Lubricate the tilting shaft via the grease nipple.
Apply grease to the bowl shaft.
Gears are not engaged
correctly
Turnopowertool.Inspectthegearringandpiniongearforalignmentandsignsof
wear.
Bearings are worn Turnopowertool.Replacewornornoisybearings.