5
General Information
Version: ECO_M_ENG_220303_E002
2.2.2. Special Requirements for Ex Installations
WARNING!
Explosion hazard
The technical specifications in the document "T100 Control drawing for hazardous areas" must be observed.
When used in potentially explosive atmospheres, the ECO must be operated via suitable isolating amplifiers
or ten barriers.
To avoid a possible ignition hazard, the versions with aluminum housing must not be exposed to shocks or
friction from other components.
NOTE:
The installation of the ECO in potentially explosive atmospheres must be carried out by appropriately
trained personnel.
If the installation is not carried out in accordance with the manufacturer's specifications, the safety for the
corresponding type of protection is invalidated.
When using long connecting cables, ensure that the maximum capacities and inductances for the
corresponding voltage and gas group are not exceeded.
If the housing of the ECO is opened by unauthorized personnel, the safety for the corresponding ignition
protection type is void.
Repairs may only be carried out by the manufacturer