- 10 -
- 11 -
- For maintenance and storage of protective glasses, see the instructions for use provided with them.
- To replace oxygen and gas cylinders it is recommended to:
a. Ensure that the cartridge is empty before replacing it.
b. For oxygen on items 555C 555D 555H200 555K: close completely the regulator by turning the
adjusting screw anticlockwise;
For oxygen on items 555KM 555H200M (with manometers) 555BM: close completely the regulator by
turning the adjusting screw clockwise;
c. For GAS: close completely the regulator by turning the orange screw clockwise.
d. Unscrew the empty cylinder
e. Screw the new cylinder and repeat steps from point (3) of the instructions for use.
- To replace the tip of the torch, unscrew the mounted tip and screw in the desired one.
Important note: NEVER use grease or oil on parts that come into contact with oxygen
Consider the following cases of malfunctioning:
1. The ame suddenly extinguishes and you can hear a loud blast due to a sudden obstruction of bit nozzle, this
blast is generated by the ignition of gas blend within the bit. The easiest solution is to allow the corpuscle to
come out from the nozzle by rubbing the bit on an appropriate tablet. If this is not successful, you should allow
the torch to cool down, then remove the bit and clean its inner part with proper material that does not scratch
its brass surface. Scratches can alter the nozzle material characteristics.
2. You hear several consecutive blasts, this is due to bit overheating after a long use of the equipment. High
temperature causes the gas blend to pre-ignite within torch. You should stop your work until bit has completely
cooled down. If you cannot interrupt your work, close the acetylene stopcock to allow oxygen ow and quick
torch cooling.
3. In case of a leaks, check that all stopcocks are closed; check that all components are properly connected and
repeat all start-up operations. If leakage persists, disconnect gas and oxygen cylinders and replace them with
appropriate replacement parts.
4. If ame is unsteady or detached, adjust gas supply by closing the oxygen stopcock and repeating all steps
from point (5).
Important note: if ller metals are used, joint has to be deoxidized with specic materials.
SAFETY
Welding equipment regulators ensure supply at a low and constant pressure. In addition, the equipment has two
non-return valves that ensure equipment safety.
WHAT TO DO IN THE EVENT OF A FIRE
Immediately close oxygen cylinder, this should be enough to extinguish the ame.
Close gas cylinder as well and extinguish re with appropriate re-ghting equipment.
RU
Руководство по эксплуатации
ВНИМАТЕЛЬНО ПРОЧИТАЙТЕ ДАННУЮ ИНСТРУКЦИЮ ПЕРЕД ТЕМ КАК НАЧНЕТЕ ПОЛЬЗОВАТЬСЯ
ИНСТРУМЕНТОМ. ПЕРЕЧИТЫВАЙТЕ ЕЕ, ЕСЛИ ЭТО НЕОБХОДИМО.
Не повреждайте оборудование. Изменение, удаление компонентов и / или использование частей, не
рекомендованных производителем может быть очень опасно.
Убедитесь в том, что оборудование используется только квалифицированными специалистами, а также
соблюдаются все законы безопасности труда.
Данное оборудование поставляется с одноразовыми кислородными баллонами (белый, арт. 571)
и газовым баллоном NOVACET (красный, арт. 580) , газовым баллоном SUPERGAS (оранжевый, арт.
575), а так же газ.бал.KEM.A.P 581,все заправлены и готовы для работы.
Строго рекомендуется использовать только оригинальные сменные части KEMPER, арт. 571
(кислородный баллон), арт. 580 (баллон NOVACET) , арт. 575 (баллон SUPERGAS), арт.581 (баллон
KEM.A.P),а так же оригинальные запчасти. Использование различных видов газовых баллонов
может быть опасно.
RU

Related product manuals