EasyManua.ls Logo

Kemper ProfiMaster KE 60650100 - User Manual

Kemper ProfiMaster KE 60650100
45 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Handleiding
Kemper ProfiMaster
KE 60650100
KE 60650101
KE 60650102
MSH equipment
Appelmarkt 7
1681 PE Zwaagdijk-Oost
Tel: 0228-561100
Fax: 0228-561112
Mail: info@msh-equipment.nl Website: www.msh-equipment.nl
Taal: Engels
Question and Answer IconNeed help?

Do you have a question about the Kemper ProfiMaster KE 60650100 and is the answer not in the manual?

Summary

SAFETY

Basics

ProfiMaster designed to recognized safety rules. Danger arises from untrained personnel, misuse, or improper servicing.

Safety instructions for the operating personnel

Personnel must read/understand manual, wear PPE (shoes, glasses, gloves), avoid loose clothing/hair, and report safety changes.

Safety instructions for maintaining and troubleshooting the ProfiMaster

Maintenance/troubleshooting only when off. Tighten screws, clean connections. Use torque wrench if required.

PRODUCT DESCRIPTION

Residual risk

Residual risks include serious injury to respiratory tract/organs and skin irritation, requiring PPE and proper operation.

ASSEMBLY

USAGE

Qualification of the operating personnel

Only appoint persons familiar with the task. Personnel must be instructed and understand the manual and company-specific instructions.

Operational controls

Details front panel components: on/off switch, signal lights, follow-up time control, maintenance jack, and connection options.

Positioning of the extraction hood

Position hood 25 cm diagonally above weld for adequate capture. Consider thermal movement and suction range.

MAINTENANCE

Changing the filter

Details filter life, recommended intervals, and procedure for replacing prefilter and main filters. Use original parts only.

Troubleshooting

Provides a table of common problems (e.g., no smoke captured, signal horn, dust emission), causes, and corrective actions.

DISPOSAL

Summary

SAFETY

Basics

ProfiMaster designed to recognized safety rules. Danger arises from untrained personnel, misuse, or improper servicing.

Safety instructions for the operating personnel

Personnel must read/understand manual, wear PPE (shoes, glasses, gloves), avoid loose clothing/hair, and report safety changes.

Safety instructions for maintaining and troubleshooting the ProfiMaster

Maintenance/troubleshooting only when off. Tighten screws, clean connections. Use torque wrench if required.

PRODUCT DESCRIPTION

Residual risk

Residual risks include serious injury to respiratory tract/organs and skin irritation, requiring PPE and proper operation.

ASSEMBLY

USAGE

Qualification of the operating personnel

Only appoint persons familiar with the task. Personnel must be instructed and understand the manual and company-specific instructions.

Operational controls

Details front panel components: on/off switch, signal lights, follow-up time control, maintenance jack, and connection options.

Positioning of the extraction hood

Position hood 25 cm diagonally above weld for adequate capture. Consider thermal movement and suction range.

MAINTENANCE

Changing the filter

Details filter life, recommended intervals, and procedure for replacing prefilter and main filters. Use original parts only.

Troubleshooting

Provides a table of common problems (e.g., no smoke captured, signal horn, dust emission), causes, and corrective actions.

DISPOSAL

Kemper ProfiMaster KE 60650100 Specifications

General IconGeneral
CategoryWelding Accessories
ModelKE 60650100
TypeProfiMaster
Voltage230 V
Power Supply230 V
Filter TypePre-filter, fine dust filter, activated carbon filter

Related product manuals