2.16 Operation of cooling unit, FastCool 10
When FastCool 10 is connected to the FastMig power source for the rst time, the cooler
function is normally active. To deselect the cooler function, follow the instructions below
depending on the power source type in use.
FastMig KMS
When leaving the factory, cooling unit status is set 'ON'. If no cooling unit is connected, set the
cooling unit status to 'OFF'. Depending on your panel type follow the instructions described
in the graphic below. Having selected the cooling state required, reset the power source by
switching o at the main on/o switch. Restart the power source and weld.
SF 51/SF 54
WIRE INCH
weld
data
V
A
m
/
min
4T
SETUP
2T
U
MMA
MIG
MMA
PANEL
SF 51
W001318
DYNAMICS
ARC FORCE
GAS TEST
GAS TEST
ARC FORCE
DYNAMICS
GAS TEST
ARC FORCE
DYNAMICS
SF 52W/SF 53W
> 5 s
SETUP
A + D B
WIRE INCH
GAS TEST
ch
ch clear
MINILOG
SET
ON
MEMORY
PANEL
SAVE
SET
quick
setup
weld
data
ARC FORCE
DYNAMICS
4T
2T
SETUP
POWER
U
SELECT
SYNERGIC
PROGRAM
MMA
WISE
1-MIG
MIG
A
V
m/min
mm
SF 52W
W004269
MMA
PEN
remote
CH
C
WIRE INCH
GAS TEST
ch
ch clear
MINILOG
SET
ON
MEMORY
PANEL
SAVE
SET
quick
setup
weld
data
ARC FORCE
DYNAMICS
4T
2T
SETUP
POWER
U
SELECT
SYNERGIC
PROGRAM
MMA
WISE
1-MIG
MIG
A
V
m/min
mm
W004269
MMA
PEN
remote
CH
SF 52W
FastMig Pulse
The factory default setting for FastMig Pulse is AUTO. If a cooling unit is not connected and
the operator tries to establish gas cooled operation together with a gas cooled gun, Err 27
is displayed. To establish gas cooled operation, select cooler ‘OFF’. This is done in the ‘System
Cong Menu as follows: Press the Menu button on the P65 power source panel. Move the
menu display arrow (via panels left-hand up-down arrow keys) to select ‘System Cong Menu
and then press select button. Choose Water Cooling:Auto and change via control knob to
setting Water Cooling:OFF’, then press Back/Exit. Cooler will then be set to the ‘OFF’ state for
Gas cooled operation. Reset power source via on/o switch and continue welding.
When selected, the operation of the cooling unit is automatic, starting when welding
commences. When welding stops the pump will continue operation for approx. 5 min,
so reducing the gun and the cooling liquid to ambient temperature. Read the operation
instructions for the FastCool 10 unit.
2.17 MXF hanging kit
The MXF 63, 65 and 67 wire feed units can be hanged from a special hanging kit available as
an accessory. This allows the wire feed unit to be suspended above the work area.
FastMig MXF 63, 65, 67