6 7
© Kemppi Oy 2020
SA 35, SA 60B, SA 60i, XA 47
2002
Shade
control
Internal Internal Automatic Internal,
digital display
Switching
time
0.1ms 0.1ms 0.1ms 0.1ms
UV/IR
protection
Always Always Always Always
Grinding
function
No Yes Ye s Ye s
Low battery
indicator
No Yes Ye s Ye s
Low
amperage
TIG rated
5A 3-5A 3-5A 5A
Power
supply,
replaceable
Solar cell,
2xCR2032
Solar cell,
2xCR2032
Solar cell,
2xCR2032
Solar cell,
1xCR2450
Certication CE, ANSI,
CSA
CE,
AS/NZS
CE,
AS/NZS
CE, ANSI,
CSA, AS/NZS
Compatible
with
Alfa e60A Beta e90A,
e90 SFA,
Delta
Beta e90Xi,
e90 XiFA
Beta e90X,
e90 XFA,
Delta+
ORDERING CODES
Model SA 35 SA 60B SA 60i XA 47
ADF SP9873061 SP9873064 SP9873075 SP9873063
* Protection
plate, inside
SP012951 SP012425 SP012425 SP012952
* There are 5 pcs of protection plate in the package.
OPERATION
Shade denes how dark the lter becomes when the arc
ignites. See the Shade level chart for the most suitable shade
level.
Sensitivity denes how easily the ADF reacts to light. Low
sensitivity is ideal for high amperage welding and welding in
bright light conditions, such as lamp light or sunlight. High
sensitivity is ideal for low amperage welding, welding in poor
light conditions and using steady arc process, such as TIG
welding.
Delay denes how long the ADF stays in the dark state to
protect eyes from the afterglow, when the arc is switched
o. MIN delay time is ideal for track welding and production
welding with short welds. MAX delay time is ideal for welding
at high amperage, where there is a strong afterglow from
the weld.
Before use
• Make sure the protective lens is clean. Remove the protec-
tive lm.
• Make sure there is no dirt covering the sensors at the front
part of the ADF.