installation
Converting the Lower
Element (cont'd)
9, Replace terminal cover on thermostat making sure that the
loddng tabs on the terminal cover are in place
Instructions (cont'd)
12, Complete wiring to the water heater, or if completed, turn
"ON" electric power to the water heater after filling the
tank with water.
_WARNING ]
Make sure the ther_gainst the tank, the |
terminal cover is in place, and the insulation is replaced. |
Fmlure to do so can result in DEATH, SERIOUS BODILY|
INJUR_,OR PROPERTY DAMAGE. ]
l& Replace the insulation block so that it completely covers
the thermostat and element,
,_ CAUTION
Never usethis water heater unless it is completely full of
water. To prevent damage to the tank and heating ele-
ment, the tank must be filled with water. Water must
flow from the hot water faucet before turning "ON"
power.
11oReplace the access panel.