Check Filter Feature -The unit tracks the amount of time that the fan runs. The
Filter light will start to flash once a second after 250 hours of operation. After
cleaning the air filter, press the Filter buffon for one second to reset this timer.
Auto-Restart - If there isa power failure, the unitwill return to the same operating
condition when the power isrestored.
Setting the Timer
* With the unit on, press the Timer button, and the Off light indicates that the Auto
Stop function may be programmed. Within 5 seconds press the UP or DOWN
buttons to select a period of time after which operation will stop. Press the Timer
button twice and the On light indicates that the Auto Start function may be
programmed. Within 5 seconds press the UP or DOWN buttons to select a period
of time after which operation will resume;With the unit off, press the Timer button,
and the On light indicates that the Auto Start function may be programmed. Within
5 seconds press the UP or DOWN buttons to select a period of time after which
operation will start. Press the Timer button twice and the Off light indicates that the
Auto Stop function may be programmed. Within 5 seconds press the UP or DOWN
button to select a period of time after which operation will stop.
* Press or hold the UP or DOWN button to change the Auto time by 0.5 hour
increments, up to 10 hours, then at 1 hour increments up to 24 hours. The control
will count down the time remaining until start or stop.
* The selected time will register for 5 seconds and the system will automatically
revert back to display the previous humidity setting.
" When the Auto start & Auto stop times are set within the same program
sequence, TIMER ON OFF indicator lights illuminate, identifying that both
ON and OFF times are now programmed.
* Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will
cancel the Auto Start/Stop function.
* The Auto Start/Stop function will also be cancelled when the protection code
P2 (bucket full) appears in the control panel display window.
WHEN USING THE UNIT
* This unit is designed to operate with a working environment between
41°F/5C ° and 95°F/35C °.
* 3 minute compressor delay - Any time the compressor stops running for any
reason, such as when the humidity set point has been reached, it will not
restart again for a minimum of 3 minutes. This is a safety design to prolong the
life of the compressor. If the fan has also stopped, it will not restart again for
3 minutes or until the compressor starts.
* Do not connect the dehumidifier to a multiple socket outlet that is also being
used for other electrical appliances.
* Select a suitable location, making sure you have easy access to an electrical outlet.
* Plug the unit into a electrical socket-outlet with a ground connection.
Make sure the water bucket is correctly fitted; otherwise the unit will not
operate properly.
NOTE: Be careful to avoid tipping the unit over while moving it when there is water
in the bucket.